Honeywell FC-TELD-0001
Honeywell FC-TELD-0001
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Monday, September 21
Fast Shipping Available
Earth Leakage Detector terminal module

FC-TELD-0001

Spare Part Number

PNFC-TELD-0001

Product Information:

The Honeywell FC-TELD-0001 is a general-purpose input/output (UIO) leakage current detection terminal module designed for safety-critical industrial automation environments. It functions as a ground fault monitor, identifying minor leakage currents before they cause serious system failures, hardware damage, or safety hazards.

It is used in Honeywell's safety management system and Experion PKS platform. It can monitor current imbalances, thereby identifying these imbalances before active insulation breakdown or ground faults escalate into hardware failures or hazardous conditions.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
Technical specifications for

FC-TELD-0001

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Honeywell
  • Product Category:
    ESD System
  • Spare Part Number:
    FC-TELD-0001
  • Estimated shipping dimensions:
    8x2x7cm
  • Weight:
    1.33 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Temperature:
    -40°C to +75°C (-40°F to +167°F )
  • Approvals:
    CE, TUV
  • DIN EN rails:
    TS32 / TS35 x 7.5
  • Used rail length:
    21 mm (0.82 in)
  • Input voltage:
    24 VDC +30/-15% (with approximately 250 Ohm series impedance)
  • Input current:
    10 mA (no earth fault present) maximum 25 mA (to be limited by the power source)
  • Earth Voltage:
    typically +4.1 VDC (with monitored 0 V as reference)
  • Earth Resistor (R):
    approximately 2.8 kOhm
  • Earth fault detection threshold:
    approximately 0.6 mA (flowing into FC-TELD-0001) approximately 0.2 mA (coming from the FC-TELD0001)
  • Termination screw terminals wire size:
    0.2 mm2 - 4 mm2 (solid) @ 0.2 mm2 - 2.5mm2 (stranded)
  • Termination screw terminals strip length:
    8 mm
  • Series:
    Honeywell Safety Systems
  • Stock Availability:
    112
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

FC TELD 0001 FC-TELD-000I FC-TELD-OOO1 FC-TELD-OOOI FC-IOTA-R24 FC-MCAR-02 FC-PDB-0824P FC-RUSIO-3224 FC-RUSLS-3224 FS-MB-0002 FS-PDC-FTA24P FS-PDC-MB24-1P FC-SCNTO2 FC-SSWM01 FC-TCNT11 TELD-0001

Information

Overview Manuals Core Application Contexts Real-World Field Deployment Examples

Features:

  • Acts as an active ground fault monitor targeting 5 VDC and 24 VDC industrial power supplies
  • Draws a baseline normal current of ~10 mA which shifts up to 25 mA during active earth fault detection states
  • Maintains a steady earth reference voltage benchmarked at +4.1 VDC to catch minor electrical shifts
The TELD-0001 is an Earth Fault Monitor in a terminal shaped housing. It is used to detect earth faults in all circuits and wiring that are galvanically connected in a power supply group. The TELD-0001 brings earth voltage to (approximately) +4Vdc as referenced to the 0Vdc of the monitored power supply group. The (0-20mA) current that is drawn by the TELD-0001 gives the control system an indication of the type of earth fault present. While no earth fault is present, the TELD-0001 will draw approximately 10mA. An earth fault current flowing through the earth connection of the TELD-0001 will change that depending on its value and polarity.

The control system can switch-off the power to the TELD-0001. This will isolate the internal TELD-0001 circuit from its earth pin. That removes the earth fault current that ran at the point in the field where the earth fault is located. The TELD-0001 needs to be connected with the RUSIO or RUSLS channel that is configured as the 'earth fault detection' channel. The module has a universal snap-in provision for standard DIN EN rails.

The FC-TELD-0001 Honeywell Earth Leakage Detector terminal module may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Honeywell FC-TELD-0001 Earth Leakage Detector terminal module Manuals(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Safety Manager (SM) Infrastructure: It connects directly to the safety loop controlled by the Honeywell Safety Manager system.
General Purpose I/O Integration: It connects specifically to the RUSIO or RUSLS (General Purpose I/O) safety module.
Critical Shutdown Systems: It protects Safety Instrumented Systems (SIS), such as Emergency Stop (ESD) systems and Fire and Gas (F&G) systems.
Offshore oil and gas platforms: Monitors cable sheath wear caused by salt spray corrosion within junction boxes, detecting it before minor grounding faults lead to unexpected platform tripping.
Chemical plants: Monitors circuits exposed to harsh, corrosive environments. The system issues an alarm if chemical residues form a conductive bridge between field instruments and structural steel.
Refinery tank farms: Protects long-distance outdoor instrument lines. The system detects moisture seeping into outdoor field enclosures, preventing it from affecting circuit readings.

Technical notes

The Honeywell FC-TELD-0001 is a 24VDC universal ground leakage current sensor module designed for general wiring solutions. It enables real-time fault detection in safety systems by monitoring current differences. This single-channel signal conditioning adapter is compatible with systems such as Experion PKS, supports intrinsically safe device protection, and features stringent industrial-grade shock and temperature resistance.
PRODUCT & ORDER FAQS

Questions buyers ask about FC-TELD-0001

  • What is the primary function of the Honeywell FC-TELD-0001?

    The FC-TELD-0001 functions as a termination or interface module for industrial control and safety systems, ensuring secure electrical integration.
  • In which critical control architecture is the FC-TELD-0001 utilized?

    It is deployed within Honeywell's Experion Process Knowledge System (PKS) and modular I/O subsystems for asset protection.
  • What robust mechanical features does the module offer?

    The module features a compact, DIN-rail mountable design for high-density panel integration in harsh industrial environments.
  • What are key electrical protection mechanisms?

    It provides high-level optical isolation and transient voltage protection to maintain signal integrity in demanding applications.
  • How does it support system uptime during maintenance?

    Designed for high availability, the module supports hot-swap capability, allowing replacement without disrupting system operations.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

FC-TELD-0001
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.