ABB CM15/20MS0E0/STD
ABB CM15/20MS0E0/STD
ABB CM15/20MS0E0/STD
ABB CM15/20MS0E0/STD
ABB CM15/20MS0E0/STD
ABB CM15/20MS0E0/STD
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Saturday, October 24
Fast Shipping Available
1/8 DIN universal process indicator

CM15/20MS0E0/STD

Product Information:

ABB ordering data decodes CM15/20MS0E0/STD as I/O build 2, Base functionality 0, RS485 Modbus M, Standard CE approval S, 100–240 V AC supply 0, English E, no special feature 0 and Standard configuration STD. Use it for process indication, alarms, totalization or dual-value display only as configured by the application. Match every ordering-code position, 1/8 DIN panel cut-out, supply, installed I/O option board, Modbus wiring and saved indicator configuration.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      ABB CM15/20MS0E0/STD is documented as a 1/8 DIN universal process indicator for ABB ControlMaster CM15. ABB ordering data decodes CM15/20MS0E0/STD as I/O build 2, Base functionality 0, RS485 Modbus M, Standard CE approval S, 100–240 V AC supply 0, English E, no special feature 0 and Standard configuration STD. Match every ordering-code position, 1/8 DIN panel cut-out, supply, installed I/O option board, Modbus wiring and saved indicator configuration.

      Official source

      ABB ControlMaster CM15 data sheet DS/CM15-EN Rev. F. Full ordering-code meanings and CM15 platform functions.
    • APPLICATIONS

      Where it may be used

      Use it for process indication, alarms, totalization or dual-value display only as configured by the application. Back up the configuration and record sensor ranges, relay assignments, analog outputs and RS485 settings before removal. Verify input scaling, displayed values, alarms, relays, analog outputs, totalizers and Modbus communications.

      Dual process indication

      Displays the configured process values on the full-color TFT.

      Expanded I O build

      Uses the code-2 option board for additional outputs, digital I/O and relays.

      RS485 Modbus link

      Integrates the indicator using the M communication code and recorded serial settings.

      Configuration recovery

      Restores scaling, alarms, totals and output assignments from the approved backup.
Technical specifications for

CM15/20MS0E0/STD

0 TECHNICAL PARAMETERS
  • Manufacturer:
    ABB
  • Product Category:
    DCS Systems
  • I/O Build Code 2:
    2 analog inputs, 2 analog outputs, 2 digital I/O and 4 relays
  • Functionality Code 0:
    Base
  • Communications Code M:
    RS485 Modbus
  • Approval Code S:
    Standard CE
  • Power Supply Code 0:
    100–240 V AC
  • Language Code E:
    English
  • Special Feature Code 0:
    None
  • Configuration Code STD:
    Standard
  • Series:
    ABB Master
  • Stock Availability:
    3
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

CM1520MS0E0STD CM15 20MS0E0 STD CM15/20MS0E0/STD

Information

Overview Manuals Ordering Code Map Input Output Setup Modbus Commissioning

Features:

  • ABB ordering data decodes CM15/20MS0E0/STD as I/O build 2, Base functionality 0, RS485 Modbus M, Standard CE approval S, 100–240 V AC supply 0, English E, no special feature 0 and Standard configuration STD.
  • Match every ordering-code position, 1/8 DIN panel cut-out, supply, installed I/O option board, Modbus wiring and saved indicator configuration.
  • Verify input scaling, displayed values, alarms, relays, analog outputs, totalizers and Modbus communications.

CM15/20MS0E0/STD must be selected from the complete manufacturer identity and the receiving-system evidence. Use it for process indication, alarms, totalization or dual-value display only as configured by the application. Back up the configuration and record sensor ranges, relay assignments, analog outputs and RS485 settings before removal.

Official source: ABB ControlMaster CM15 data sheet DS/CM15-EN Rev. F. Full ordering-code meanings and CM15 platform functions.
CM15/20MS0E0/STD official technical documentation and related ABB resources.Important Notice: Confirm the complete article number and installed configuration before replacement. Each link opens in a new page.

Each character in 20MS0E0/STD identifies the installed I/O, function, communication, supply and configuration.

Verify universal inputs, analog outputs, digital I/O and four relay assignments against the loop sheets.

Restore address, baud rate, parity and register mapping, then compare values with the host system.

Technical notes

CM15/20MS0E0/STD must be controlled by its complete identity. Full ordering-code meanings and CM15 platform functions. Back up the configuration and record sensor ranges, relay assignments, analog outputs and RS485 settings before removal. Verify input scaling, displayed values, alarms, relays, analog outputs, totalizers and Modbus communications.

20MS0E0 STD Decoded

Code 2 selects two analog inputs, two analog outputs, two digital I/O and four relays; 0 selects Base functionality; M selects RS485 Modbus; S is Standard CE; the next 0 is 100–240 V AC; E is English; 0 means no special feature; STD means Standard configuration.

Process Signal Setup

Before replacement, export or record each input type and range, linearization, totalizer, alarm, relay and analog-output assignment. After loading them, compare the CM15 display and Modbus values with independent process references.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    1/8 DIN panel instrument; packed size to confirm
  • Packed shipping weight
    Confirmed after final packing
    3.24 kg listed item weight requires packing confirmation
  • HS / customs code
    Preliminary HS heading 9026.80
    Confirm destination-country classification before shipment.
  • Country of origin
    Not officially confirmed
    Verify against the supplied item nameplate or certificate of origin.
  • Ships from
    Xiamen, Fujian, China
    Dispatch location is confirmed in the written quotation.
  • Customs documents
    Confirmed for the destination
    Available document scope is stated in the written quotation.
PRODUCT & ORDER FAQS

Questions buyers ask about CM15/20MS0E0/STD

  • How is the exact CM15/20MS0E0/STD identified?

    ABB ordering data decodes CM15/20MS0E0/STD as I/O build 2, Base functionality 0, RS485 Modbus M, Standard CE approval S, 100–240 V AC supply 0, English E, no special feature 0 and Standard configuration STD. Use every printed article, suffix and revision together.
  • What must match before installing CM15/20MS0E0/STD?

    Match every ordering-code position, 1/8 DIN panel cut-out, supply, installed I/O option board, Modbus wiring and saved indicator configuration.
  • What technical role does CM15/20MS0E0/STD perform?

    Use it for process indication, alarms, totalization or dual-value display only as configured by the application.
  • Which preparation is required before replacing CM15/20MS0E0/STD?

    Back up the configuration and record sensor ranges, relay assignments, analog outputs and RS485 settings before removal.
  • How should CM15/20MS0E0/STD be commissioned?

    Verify input scaling, displayed values, alarms, relays, analog outputs, totalizers and Modbus communications.
  • Which source supports the listed CM15/20MS0E0/STD information?

    ABB ControlMaster CM15 data sheet DS/CM15-EN Rev. F. Full ordering-code meanings and CM15 platform functions.
  • Are unverified nearby-model specifications used for CM15/20MS0E0/STD?

    No. Values that cannot be tied to the complete CM15/20MS0E0/STD identity are withheld rather than copied from a visually similar product.
  • What ordering evidence should be supplied for CM15/20MS0E0/STD?

    Provide the required quantity, clear nameplate photographs, the receiving equipment identity, installed revision and delivery destination so the exact supply scope can be confirmed.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Availability and lifecycle status are confirmed for the exact CM15/20MS0E0/STD article at quotation.

    Moore Automated verifies the supplied condition, included items and installed-system match against the complete manufacturer identity.

    The replacement must be commissioned with the checks listed in the technical sections.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

CM15/20MS0E0/STD
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.