Features:
- 5 mm Standard Mount Probe
- 7200 Proximity Transducer Systems 5 mm and 8 mm
- Noncontacting, gap-to-voltage transducer systems
An improved 8 mm version of the 7200 System is now standard which includes Bently Nevada's Cable LoC™ feature. This new technique of securing the coaxial cable to the probe tip provides the strongest junction yet offered by Bently Nevada and increases the durability of the probe during installation and usage. Two new cable length options are now available on 8 mm probes. They are 5 metres and 9 metres of integral cable. Since the entire lead-length is built into the probe, an extension cable is not used with these length options.
Nine probe configurations are available to accommodate English and metric thread requirements. The 5 mm probes are constructed of fiberglass. The 8 mm probes are constructed of polyphenylene sulfide, (PPS), a high performance plastic capable of withstanding unusually harsh, wet and/or chemical environments. Both transducers are suitable for use in a confined space and offer 80 mils (2 mm) of linear range with a scale factor of 200 mV/mil (8 V/mm).
The 21501-00-16-05-02 Bently Nevada 5 mm Standard Mount Probe may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Bently Nevada 21501-00-16-05-02 5 mm Standard Mount Probe Manuals(Datasheets), Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
- Model: 21501-00-16-05-02
- Warranty: One-year warranty
- Condition: Brand new, original, in stock
- Product Family: 5 mm and 8 mm 7200 Proximity Transducer Systems
5 mm and 8 mm Standard Mount Probe
21501-Axx-Bxx-Cxx-Dxx
A: Unthreaded Length
Order in increments of 0.4 inches 04 for English thread,
10 mm 01 for metric threads.
English thread configurations:
Maximum unthreaded length: 8.8 inches 88
Minimum unthreaded length: 0.0 inches 00
Example: 04 = 0.4 inches
Metric thread configuration:
Maximum unthreaded length: 230 mm 23
Minimum unthreaded length: 0.0 mm 00
Example: 06 = 60 mm
B: Overall Case Length
Order in increments of0.4 inches 04 for English thread,
10 mm 01 for metric threads.
English thread configurations:
Maximum case length: 9.6 inches 96
Minimum case length: 0.8 inches 08
Example: 24 = 2.4 inches
Metric thread configuration:
Maximum length: 250 mm 25
Minimum length: 20 mm 02
Example: 04 = 40 mm
C: Total Length
05: 0.5 metre (20 inches)
10: 1.0 metre (39 inches)
50: 5 metre (195 inches)
90: 9 metre (351 inches)
D: Connector
00: Without connector.
02: With miniature male coaxial connector.
The 7200 5 and 8 mm Systems have a frequency response of 0 Hz (DC) to 10 kHz and can be used to make the following types of measurements:
• Radial vibration for indicating bearing condition and such machine
malfunctions as rotor imbalance and misalignment.
• Axial thrust position for determining thrust bearing wear or
potential bearing failure.
• Shaft average radial position, for determining attitude angle, an indicator of rotor stability.
• Vibration amplitude and phase angle for plotting diagnostic information in Polar and Bode formats.
• Eccentricity to measure the amount of rotor bow.