Request a Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
General Electric DS200TCQAG1BFD DS215TCQAG1BZZ01A
General Electric DS200TCQAG1BFD DS215TCQAG1BZZ01A
General Electric DS200TCQAG1BFD DS215TCQAG1BZZ01A
General Electric DS200TCQAG1BFD DS215TCQAG1BZZ01A
General Electric DS200TCQAG1BFD DS215TCQAG1BZZ01A
General Electric DS200TCQAG1BFD DS215TCQAG1BZZ01A
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Monday, September 21
Fast Shipping Available
Analog I/O Board Circuit Board

DS200TCQAG1BFD DS215TCQAG1BZZ01A

Spare Part Number

PNDS200TCQAG1BFD DS215TCQAG1BZZ01A

Product Information:

The DS200TCQAG1BFD DS215TCQAG1BZZ01A refer to the same functional hardware unit: a dedicated analog I/O (TCQA) board manufactured by General Electric (GE). The main difference between these two part numbers lies in their production batch and components. DS200 represents a basic/traditional printed circuit board (PCB) design, while DS215 represents a later-stage factory upgrade production batch that integrates factory-installed firmware and optional software modifications onto the board.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
Technical specifications for

DS200TCQAG1BFD DS215TCQAG1BZZ01A

0 TECHNICAL PARAMETERS
  • Manufacturer:
    General Electric
  • Product Category:
    Gas Turbine Control
  • Spare Part Number:
    DS200TCQAG1BFD DS215TCQAG1BZZ01A
  • Estimated shipping dimensions:
    27.8x21.2x2cm
  • Weight:
    0.65 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Product Type:
    Analog I/O Board
  • Category Series:
    Mark V DS200 System
  • Functional Acronym:
    TCQA
  • PCB Coating:
    Normal Coating
  • Voltage Range:
    0 - 10V DC
  • Current Capacity:
    4-20 mA
  • Resolution Rating:
    12 bits
  • Operating Voltage:
    24V DC
  • Operating temperature:
    -25°C to +60°C
  • IP degree of protection:
    IP20
  • Series:
    GE Mark V and Mark VI Turbine Controls
  • Stock Availability:
    120
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

DS200TCQAG1BFD DS215TCQAG1BZZ01A DS200TCQAG1B DS215TCQAG1BZZ0 DS200 TCQAG1BFD DS215 TCQAG1BZZ0 DS2I5TCQAGIBZZ0 DS2OOTCQAG1BFD DS200TCQAGIBFD DS200TCDAG1BFD DS200TCQAG1ADB DS200TCQAG1ADC DS200TCQBG1BCB

Information

Overview Manuals Functional Role Operating principle

Features:

  • Circuit Board with Firmware
  • GE Boards & Turbine Control Mark V DS200 Series
  • Deployed within the main control core, it is used to regulate heavy-duty gas turbines and steam turbines
The main function of DS200TCQAG1BFD DS215TCQAG1BZZ01A is to provide high-capacity, high-precision analog signal acquisition and conditioning for gas turbines and steam turbines. This board is a key link connecting the turbine's field physical sensors with the system's main processor, directly affecting the unit's operating efficiency and the accuracy of the main control logic.

The inputs support LVDT (Linear Variable Differential Transformer) position feedback required for precision control valves, thermocouple signals required for critical unit temperature control, vibration signals for monitoring equipment health, pulse counting, and standard 4-20 mA current input. The outputs provide high dynamic response servo valve outputs and 4-20 mA analog control signals for real-time adjustment of the equipment's intake and fuel valves, ensuring absolutely safe and stable operation under high overload and complex industrial environments.

The DS200TCQAG1BFD DS215TCQAG1BZZ01A General Electric Analog I/O Board Circuit Board may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
General Electric DS200TCQAG1BFD DS215TCQAG1BZZ01A Analog I/O Board Circuit Board INFO(manual), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The TCQA board is the core signal conditioning interface between the turbine hardware and the control system. It scales and filters a large number of critical analog signals, including:
Inputs: Linear Variable Differential Transformer (LVDT), thermocouples, vibration sensors, pulse inputs, and standard 4-20 mA process inputs (e.g., compressor stall detection and fuel flow/pressure).
Outputs: Electro-hydraulic servo valve driver current, relay driver signals, and 4-20 mA monitoring outputs.
The TCQA analog I/O board operates based on a hardware closed-loop signal conditioning and multi-level parallel processing architecture. When a weak analog voltage or current is received from the device via field terminals (e.g., the R1, R2, and R3 core racks), the signal first enters the onboard signal conditioning circuitry for isolation, filtering, and scaling, converting it into a nominal voltage recognizable by the internal analog-to-digital converter (ADC).
The converted digital signal is then written directly to the RAM registers of the upper-level control system or the STCA motherboard via a high-speed bus interface (e.g., a 3PL connector), for use by the system's triple redundant processors (R, S, and T cores) in control algorithm calculations.
Simultaneously, the onboard drive circuitry receives control commands from the microprocessor in real time. Through an internal digital-to-analog converter (DAC) and power amplification, the electrical signal is converted into a precise current output, dynamically driving a servo valve actuator, thus forming a complete high-speed field industrial closed-loop control process.

Technical notes

The DS200TCQAG1BFD DS215TCQAG1BZZ01A (both using the TCQA core model) are core analog input/output expansion boards (RST analog I/O boards) in the GE Speedtronic Mark V steam turbine and gas turbine control system. Onboard hardware jumpers (e.g., J1 to J8) are used to switch current output ranges and perform board testing, while software configuration of corresponding I/O constants is required to support high availability and safe operation of the Mark V system in single-machine, dual-redundant, or triple-redundant architectures.
PRODUCT & ORDER FAQS

Questions buyers ask about DS200TCQAG1BFD DS215TCQAG1BZZ01A

  • Why are GE DS200TCQAG1BFD and DS215TCQAG1BZZ01A widely used in gas turbine and steam turbine applications requiring deterministic signal transmission and reliable field wiring termination?

    The DS200TCQAG1BFD and DS215TCQAG1BZZ01A provide stable signal routing and secure field connections, thereby improving the reliability of the control system.
  • How do the GE DS200TCQAG1BFD and DS215TCQAG1BZZ01A maintain signal integrity when handling multiple analog and discrete control channels in high-noise industrial environments?

    The DS200TCQAG1BFD and DS215TCQAG1BZZ01A employ industrial-grade circuit design and terminal isolation to reduce signal degradation and electromagnetic interference.
  • When commissioning GE DS200TCQAG1BFD and DS215TCQAG1BZZ01A in the turbine control cabinet, what electrical installation parameters should the engineer verify?

    Commissioning of DS200TCQAG1BFD and DS215TCQAG1BZZ01A should include verifying terminal assignments, grounding integrity, wiring continuity, connector engagement, and insulation resistance.
  • Why are the GE DS200TCQAG1BFD and DS215TCQAG1BZZ01A considered key components for maintaining deterministic turbine protection and control functions?

    The DS200TCQAG1BFD and DS215TCQAG1BZZ01A provide reliable field signal connections, supporting protection logic, alarm handling, and control system execution.
  • How do the GE DS200TCQAG1BFD and DS215TCQAG1BZZ01A support high-density field signal management while maintaining structured cabling?

    The DS200TCQAG1BFD and DS215TCQAG1BZZ01A offer optimized terminal layouts that facilitate efficient field cabling and signal isolation.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

DS200TCQAG1BFD DS215TCQAG1BZZ01A
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.