Honeywell CC-PWRN01
Honeywell CC-PWRN01
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Tuesday, October 20
Fast Shipping Available
Non-Redundant Power System

CC-PWRN01

Spare Part Number

PN51199937-100

Product Information:

CC-PWRN01 is the single-supply, non-redundant 20 A power subsystem for Honeywell Series C control hardware. It accepts nominal 120/240 V AC and powers the cabinet DC distribution; it does not include a second supply or a 24 V battery-backup assembly.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      CC-PWRN01 is Honeywell assembly 51199937-100, a non-redundant Series C power subsystem containing one AC-powered supply. The 20 A output rating is intended for an engineered combination of controller, I/O and field-power loads. Unlike the redundant versions, this arrangement has no partner supply to carry the load during a supply failure or removal. It also has no main 24 V backup battery assembly, so maintenance planning must account for interruption of the cabinet power path.

      Selection basis

      Confirm that a single-supply arrangement is appropriate for the installed cabinet. Check the complete 51199937-100 assembly, incoming AC protection and connected DC load; an upgrade to redundancy requires the correct engineered system, not merely a similar spare supply.
    • APPLICATIONS

      Where it may be used

      Potential uses where the approved control design permits a non-redundant DC power subsystem.

      Food & Beverage

      Supplies DC power for approved single-feed process-control cabinets.

      Water & Wastewater

      Energizes treatment I/O where planned power interruptions are acceptable.

      Mineral Processing

      Powers non-redundant control hardware for auxiliary processing equipment.

      Industrial Chemicals

      Feeds cabinet electronics within an engineered single-supply power budget.
Technical specifications for

CC-PWRN01

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Spare Part Number:
    51199937-100
  • System Configuration:
    One power supply; non-redundant 20 A system
  • Rated DC Capacity:
    20 A
  • Nominal AC Input:
    120/240 V AC
  • AC Operating Band:
    100-230 V AC RMS
  • AC Operating Limits:
    85-264 V AC RMS
  • Input Frequency:
    47-63 Hz
  • DC Output Specification:
    24-26 V DC
  • Holdup Time:
    20 ms
  • Maximum Inrush Current:
    35 A peak
  • Minimum Efficiency:
    65%
  • Power-System Operating Temperature:
    0 to 60 °C
  • Battery Backup:
    No 24 V backup battery assembly
  • Stock Availability:
    6
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

CCPWRN01 CC PWRN01 Honeywell CC-PWRN01 51199937-100

Information

Overview Manuals Single-Supply Design Output Load Budget Outage Preparation

Features:

  • One power supply serves a non-redundant 20 A Series C load.
  • Nominal 120/240 V AC input with a 24-26 V DC output specification.
  • No second supply or 24 V backup assembly is included in this configuration.

The Honeywell CC-PWRN01 provides the single normal power path for a non-redundant Series C cabinet. Honeywell lists the configuration as assembly 51199937-100, containing one supply and a 20 A system capacity. Its regulated output feeds compatible distribution hardware serving the controller, I/O and associated field loads. The system specification gives a 100-230 V AC operating band, an 85-264 V AC operating-limit range and a 47-63 Hz frequency range; these descriptions should not be collapsed into an unsupported nominal rating.

Because no partner supply or 24 V backup assembly is included, removing the supply can interrupt all equipment dependent on that power path. Plan replacement with operations personnel and qualified electrical staff, using the cabinet drawings to identify the affected loads and the proper isolation point. After installation, check protective earth, supply output and alarm reporting before the process is returned to service. An intended redundancy or battery-backup upgrade requires review of the complete power-system design and supplied components.

The CC-PWRN01 Honeywell Non-Redundant Power System may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Honeywell CC-PWRN01 documentation and reference links.Important Notice: These selected original Honeywell pages retain both document covers. Electrical ratings, component scope and service-life advice must be read with their stated conditions; the service note is not an EOL announcement.

Only one power supply is included in this configuration. Before selecting it, establish which controller and field circuits depend on its output and what the process does if that output is lost. A non-redundant power subsystem should not be described as providing a failover path.

The system capacity is 20 A. Sum controller, I/O and any field-power consumption supplied by the cabinet distribution, including the conditions required by the engineering design. The nominal 120/240 V AC input describes the supply arrangement; it does not determine the allowable DC load independently of the system rating.

Coordinate replacement with the approved process shutdown or transfer procedure because this configuration has no second supply to carry the load. Identify the incoming isolation point and verify the affected circuits before work. On restoration, check output and alarms and complete the required operational checks before releasing the cabinet.

Technical notes

CC-PWRN01 is the single-supply 20 A Series C subsystem, assembly 51199937-100. It includes neither a redundant partner supply nor the 24 V backup assembly. Plan isolation and return-to-service checks for the cabinet loads that depend on this sole power path.

Single-Path Power Compatibility

Assembly 51199937-100 is the non-redundant 20 A Series C system. Match the supply arrangement, DC distribution and connected load with the installed design. If the application requires continuity after a supply failure, this configuration alone does not meet that requirement. Review a suitable redundant system and its installation requirements rather than assuming two loose supplies can be fitted interchangeably.

Isolation and Return to Service

Determine the consequences of removing the sole supply before starting work. Qualified personnel should follow site isolation, lockout and electrical-safety procedures, then check the replacement assembly and connections against the approved drawings. After power is restored, confirm the correct DC output and alarm state and verify that the dependent controller and I/O have returned to their required operating condition.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Measured for the supplied configuration
    The referenced Honeywell specification does not give exact assembly shipping dimensions. The complete system and loose supply are different shipment scopes; carton dimensions are recorded after protective packing.
  • Packed shipping weight
    Gross weight confirmed on the packing list
    No verified exact-assembly net mass is stated in the cited source. Do not substitute an I/O-module weight; the weighed shipment includes the agreed assembly and accessories.
  • HS / customs code
    850440 (indicative)
    Six-digit reference for static-converter power equipment. The customs declarant must determine the final destination tariff line and the treatment of any separately supplied batteries or accessories.
  • Country of origin
    Verify the supplied assembly marking
    Honeywell brand ownership is not proof of origin. The country recorded for shipment must match the actual assembly label and origin documents.
  • Ships from
    Xiamen, Fujian, China
    Quantity, supplied condition and dispatch timing are confirmed in the written quotation.
  • Customs documents
    Invoice, packing list and agreed origin evidence
    Confirm destination requirements before dispatch. Battery-inclusive shipments also require review of the actual battery type and carrier documentation.
PRODUCT & ORDER FAQS

Questions buyers ask about CC-PWRN01

  • How many supplies are included with CC-PWRN01?

    One. Honeywell identifies assembly 51199937-100 as the non-redundant 20 A power subsystem.
  • Does it keep the cabinet powered if the supply fails?

    No second supply is included to carry the load. The effect of a failure depends on the cabinet and plant power design.
  • What input and output ratings are documented?

    The nominal input is 120/240 V AC, with a 47-63 Hz frequency range. The system specification gives a 24-26 V DC output and a 20 A system capacity.
  • Where might a non-redundant system be selected?

    It may be considered for auxiliary or process-control cabinets where the engineered design permits a single power path and the operational consequences of losing that path are acceptable.
  • Can it be exchanged while the cabinet remains operating?

    Do not assume so. With only one supply, replacement can interrupt cabinet power. Use the approved outage, isolation and commissioning procedures for the installed system.
  • How do I check availability of CC-PWRN01?

    Send the quantity and confirm whether you need the complete 51199937-100 subsystem or an individual spare. Moore Automated will confirm allocated stock and condition in writing.
  • What warranty is offered for this subsystem?

    The supplied item carries a one-year Moore Automated warranty under the agreed sales terms. The written quotation defines the included components and warranty conditions.
  • How is the dispatch package specified?

    Packing is selected for the actual assembly and accessories supplied. The final packing list records carton dimensions and gross weight; request the destination-specific shipping quotation before ordering.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Honeywell includes CC-PWRN01 in its January 2025 Series C power-system service guidance. That document addresses installed-equipment maintenance and does not declare a model-specific discontinuation date. A current OEM lifecycle designation has not been established by the cited sources, so this page does not label the product Active or Discontinued.

    Power-supply age and condition should be reviewed against Honeywell maintenance guidance, including the increased failure risk around ten years of service. Moore Automated can confirm the condition, included components and availability of the quoted item; service-life estimates do not extend the OEM rating or establish remaining useful life.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

CC-PWRN01
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.