ICS Triplex T9802
ICS Triplex T9802
ICS Triplex T9802
ICS Triplex T9802
ICS Triplex T9802
ICS Triplex T9802
· Product image is representative; revision or series may vary. Contact us to request a specific version.

T9802

Digital Input FTA Module
In Stock
Ships by Friday, August 7
Fast Shipping Available

Product Information:

The ICS Triplex T9802 is a 16-channel dual digital input terminal block (TA). It serves as a physical field interface, routing input process signals to a pair of redundant T9401 or T9402 digital input modules. This product is IEC 61508 certified, with a safety level up to SIL 3 (Safety Integrity Class 3), making it suitable for high-availability, safety-critical industrial circuits.

This board features robust isolation withstand voltage up to ±1.5 kVdc, advanced channel status and power diagnostics, and an operating temperature range of -40°C to... Even in harsh industrial environments with temperatures up to +70°C and vibration, it can safely and efficiently regulate and transmit signals from field limit switches or proximity sensors to the controller body.

Expand All
Collapse all

Technical specifications for T9802

  • Manufacturer:
    ICS Triplex
  • Product Category:
    SIS System
  • Estimated shipping dimensions:
    13.1x8.4x3.5cm
  • Weight:
    0.14 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Field Connections:
    16; wiring: Conductor cross section maximum 1.31 mm² (16 AWG); Stripping length 6 mm (¼ in.)
  • Input modules supported:
    Two (2)
  • Input channel fuses:
    50 mA, 125 V, Type T manufactured by Littelfuse
  • Channel load:
    (5.125 ± 0.2 %) kΩ
  • Input measurement voltage resolution:
    5 mV, 13 bit
  • Channel isolation:
    ± 1.5 kVdc maximum withstanding for 1 minute
  • Product Type:
    Digital Input DI
  • Stock:
    30

Alternative Names

T98O2 T9B02 T9BO2 T9803 T9831 T9832 T9833 T9851 T9852 T9881 T9882 T9100 T9831 T9482 T9451 T9431

Information

Overview Manuals Principle Industry Applications

Features:

  • Redundant I/O 16-Ch Digital Input Module
  • Triple Modular Redundant (TMR), fault tolerant (3-2-0) operation
  • Hardware Implemented Fault Tolerant (HIFT) architecture
The Trusted TMR processor is a fault-tolerant design based on a Triple Module Redundancy (TMR) architecture, operating in a synchronous configuration. Figure 1 illustrates the basic structure of the Trusted TMR processor module in a simplified manner.

The module comprises three Processor Fault Isolation Regions (FCRs). Each FCR contains an NXP PowerQUICC® II™ series processor and its associated memory (EPROM, DRAM, Flash ROM, and Flash RAM), memory-mapped I/O, a voter, and glue logic. Each processor FCR employs a 2/3 (2oo3) read permission voting mechanism to vote on the memory systems of the other two processor FCRs to eliminate operational discrepancies.

The T9802 ICS triplex Redundant I/O 16-Ch Digital Input Module may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
ICS Triplex T9802 Redundant I/O 16-Ch Digital Input Module maunal(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The three processors in this module are responsible for storing and executing applications, scanning and updating I/O modules, and detecting system faults. Each processor executes applications independently but operates synchronously with the other two processors. Each processor has an interface that includes an input voter, discrepancy detection logic.
T9802 is widely used in the following high-risk industries:
Oil & Gas: Refinery, offshore platform, and pipeline monitoring.
Power Generation: Safety control for nuclear and thermal power plants.
Chemicals: Batch management and safety interlocks for reactive chemicals.
Manufacturing: Heavy industries such as steel smelting and automobile manufacturing.

Technical notes

The ICS Triplex T9802 is a dual-redundant 16-channel digital input terminal block (DITA) for the AADvance safety control system (formerly the 9000 series). This terminal block is designed for high-safety, high-availability industrial applications such as electrostatic discharge (ESD) emergency shutdown and fire gas distribution monitoring, and is specifically designed for use with the T9401/2 digital input module. Its physical architecture supports dual-redundant signal termination. Electrically, it includes 16 field input channels (operating voltage 18~32V DC), each channel integrating an independent 5.125 kΩ high-impedance load to reduce the load on field devices, and equipped with a 50mA/125V T-type fuse for comprehensive channel-level overcurrent protection.

Ask our team:

  • What are the main operational functions of the T9802 in high integrity or safety instrumented control systems?
    The T9802 is primarily used as a digital output interface module, responsible for performing precise switching operations to drive field devices in response to control logic. It reliably executes automation commands in safety-critical and industrial environments.
  • How does the T9802 ensure accurate and stable output drive in industrial environments with high electrical noise or harsh conditions?
    The T9802 integrates advanced output drive circuitry, electrical isolation, and transient suppression components. These design features effectively suppress electromagnetic interference (EMI), voltage spikes, and switching transients, thereby ensuring reliable and accurate drive of connected loads.
  • In which industrial sectors is the T9802 best suited? What are its advantages in terms of system reliability?
    The T9802 is commonly used in industries such as oil and gas, power generation, and process automation, where deterministic and fail-safe output control is crucial. It enhances system availability, ensures safe execution of shutdown and interlocking sequences, and improves the accuracy of overall process control.
  • What types of loads and actuators can the T9802 connect to? How is output performance controlled?
    The T9802 supports a variety of discrete loads, including relays, solenoid valves, and indicators. Output channels are driven by controlled switching circuitry, enabling precise on/off control while maintaining electrical isolation and load protection.
  • What diagnostic and monitoring functions does the T9802 integrate to enhance maintainability and operational visibility?
    The T9802 features comprehensive diagnostic capabilities, such as channel status monitoring, open/short circuit detection, and output verification. These mechanisms enable operators to proactively identify and maintain faults without impacting system uptime.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.