T9882

Analog Output FTA Module
In Stock
Ships by Saturday, July 25
Fast Shipping Available

Product Information:

The ICS Triplex T9882 is an 8-channel dual-redundant general-purpose analog output terminal block (TA). It serves as a physical field interface, routing precise analog command variables to proportional field actuators, control valves, variable speed drive reference sources, or industrial chart recorders. This product is certified for use in safety-critical industrial circuits compliant with IEC 61508, achieving a Safety Integrity Level (SIL) of up to 3.

It integrates precise channel-level AC/DC electrical isolation, a reverse current protection diode network, and transient overvoltage suppression (TVS) protection, effectively preventing inter-module signal interference or reverse DC current flow. In complex industrial applications, it provides extremely high signal output accuracy (safety accuracy up to 200 μA) and high reliability.

Expand All
Collapse all

Technical specifications for T9882

  • Manufacturer:
    ICS Triplex
  • Product Category:
    SIS System
  • Estimated shipping dimensions:
    2.2 cm x 12.4 cm x 12.6 cm
  • Weight:
    0.23 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Product Type:
    Analog Output FTA
  • Category Series:
    TMR
  • Number of channels:
    8 channels
  • Field connections:
    8 connections
  • Wiring:
    Conductor cross section maximum 1.31 mm² (16 AWG); Stripping length 6mm (¼ in.)
  • Modules supported:
    Two
  • Channel isolation:
    ± 1.5 kVdc maximum withstand for 1 minute
  • Current Capacity:
    4 to 20 mA
  • CE Compliant:
    Safety Integrity Level 3 (SIL 3)
  • Stock:
    100

Alternative Names

T9BB2 T9802 T9803 T9831 T9833 T9851 T9310 T9852 T9832 T9881 T9844 T9845 T9846 T9847 T9848 T9849

Information

Overview Manuals Functional Safety & System Integration Certifications & Standards

Features:

  • 8 analog output channels
  • 24 VDC nominal (functional backplane input range of 18 VDC to 32 VDC)
  • Its robust electrical isolation enables it to withstand a maximum voltage of up to ±1.5 kVDC for 1 minute to protect the internal safety processor from field voltage spikes
The core function of the T9882 is to distribute control commands from the AADvance system to eight independent analog channels in the field. It is seamlessly compatible with voltage and standard 4–20mA current signals, enabling high-precision driving and precise regulation of critical field devices such as proportional control valves, frequency converters, servo mechanisms, and electric actuators.

Compared to single-rack components, the most significant feature of the T9882 is its robust dual hardware fault tolerance and high isolation between channels. Its dual-module plug-in architecture allows two T9482 analog output modules to be connected to the same terminal component simultaneously, thereby physically eliminating the risk of single point of failure and preventing control loop interruptions due to the failure of a single output card.

The T9882 ICS triplex Analog Output FTA Module may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
ICS Triplex T9882 Analog Output FTA Module maunal(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The T9882 is the physical wiring basis for connecting two T9481 or T9482 AADvance analog output modules. Evaluated and certified by TÜV Rheinland, it meets the SIL 3 safety level requirements of IEC 61508 and is widely used in high-risk environments such as oil and gas emergency shutdown (ESD) systems, fire and gas (F&G) systems, and critical petrochemical process control.
IEC 61508: Formal certification for safety-critical applications, with a maximum safety level of SIL 3, employing a dual (redundant) hardware architecture loop.
IEC 61511-1: Validated for use in safety instrumented systems designed specifically for process industry automation applications.
EN 50156-1: Approved for integration into electrical control equipment for industrial furnaces and auxiliary system heaters.
EN 54-2: Approved for use in critical fire detection, suppression, and alarm control systems.
ATEX/UKEX: Explosive atmosphere certification compliant with EU Directive 2014/34/EU.
IECEx Certification System: Certified by the international IECEx certification system (Certificate: IECEx UL 12.0032X).
UL/cUL HazLoc: Certified by Underwriters Laboratories (UL) for Class I, Zone 2, A, B, C, and D hazardous locations.
EN 61131-2:2007: Standard product specification conforming to programmable logic controllers, electrical safety standards and stringent A/B area electromagnetic compatibility testing.

Technical notes

The ICS Triplex T9882 (now a Rockwell Automation product) is a dual-redundant 8-channel analog output terminal block for AADvance safety and process control systems. This terminal block is designed for critical process control loops requiring high safety and availability. As the physical wiring assembly between a field terminal and two T9481 or T9482 analog output modules, its physical architecture supports dual-redundant signal termination and hot-repair, ensuring uninterrupted control output in the event of a single module failure or in-line replacement. Electrically, it provides eight standard analog output channels supporting standard industrial voltages from 4 to 20 mA. Current-loop output signals and an overall common-ground electrical architecture simplify grounding for large-scale field cabling.
  • Product Lifecycle Stage

    Obsolete/Discontinued by OEM

    Moore Automated provides high-quality ICS Triplex replacement modules and spare parts for legacy and obsolete safety systems. Our reliable solutions help minimize customer downtime, extend equipment life, and ensure the continuous operation of critical industrial processes.

Ask our team:

  • How does the T9882 leverage its fault-tolerant communication architecture and deterministic data processing capabilities to maximize the operational integrity of high-availability safety instrumented systems (SIS)?
    The T9882 is designed for mission-critical industrial automation and safety applications, providing deterministic communication, reliable data exchange, and continuous stable operation.
  • What are the key technical specifications of the T9882? These specifications include communication interfaces, supported network architectures, power characteristics, environmental operating range, and hardware compatibility.
    The T9882 employs an industrial-grade electronic architecture designed to operate within specific electrical and environmental parameter ranges while maintaining reliable long-term performance.
  • Why is the T9882 considered a mission-critical module in redundant industrial control systems, requiring continuous fault-tolerant communication and deterministic response?
    The T9882 supports high-integrity communication and reliable operational behavior, making it suitable for applications with extremely high requirements for continuous system availability.
  • How does the T9882 maintain deterministic communication latency and superior signal integrity under high-load industrial network operation and harsh process conditions?
    The T9882 employs robust communication management and industrial-grade hardware design to ensure stable communication performance and predictable response characteristics.
  • How does the T9882 enhance the resilience of automation systems through redundant communication mechanisms, intelligent diagnostics, and a high-availability architecture?
    The T9882 provides reliable communication capabilities and comprehensive fault monitoring, supporting uninterrupted industrial operation.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.