ICS Triplex TC-205-02-12M5
ICS Triplex TC-205-02-12M5
· Product image is representative; revision or series may vary. Contact us to request a specific version.

TC-205-02-12M5

I/O Companion Slot, Internal, 40 Channel Output to FTA, 12.5m
In Stock
Ships by Wednesday, August 5
Fast Shipping Available

Product Information:

The TC-205-02-12M5 is an I/O cable specifically designed for Trusted systems, manufactured by ICS Triplex, a subsidiary of Rockwell Automation. As a core connection component in high-safety, triple-redundant (TMR) critical control systems, it is specifically designed for safe output loops, establishing physical electrical connections between Trusted digital or analog output modules (such as the T8451 24Vdc output module, T8461, etc.) and the field terminal assembly (FTA) board within the cabinet.

The TC-205-02-12M5's outer sheath is made of advanced low-smoke halogen-free (LSOH/LSLH) highly flame-retardant material, meeting the stringent testing requirements of international IEC standards. In the event of a fire, it significantly reduces the release of toxic fumes and corrosive gases. To address potential signal attenuation and noise interference risks over a 12.5-meter transmission distance, the cable features a high-density braided shield and is equipped with dedicated safety grounding wires at both ends.

In addition, the outer layer is reinforced with a wear-resistant and shock-absorbing nylon protective sleeve, and both ends are equipped with anti-crack technology to ensure that critical linkage shut-off and valve drive commands maintain zero distortion and extremely high data integrity during long-distance transmission. The TC-205-02-12M5 hardware is typically used in emergency safety shutdown (ESD) systems in the oil and gas and refining industries, as well as fire and gas (F&G) protection systems on critical production lines.

Expand All
Collapse all

Technical specifications for TC-205-02-12M5

  • Manufacturer:
    ICS Triplex
  • Product Category:
    SIS System
  • Estimated shipping dimensions:
    12.6 x 15 x 14.3 cm
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Product Type:
    I/O Companion Slot Cable
  • Category Series:
    TMR system
  • Number of channels:
    40 channels
  • Cable Length:
    12.5-meter
  • Operating Voltage:
    24 V/120 V DC
  • Current Capacity:
    4-20 mA
  • Operating temperature:
    -30 ... +80 °C (-22 ... +176 °F)
  • Stock:
    11

Alternative Names

TC2050212M5 TC 205 02 12M5 TC-2O5-O2-12M5 TC-205-02-I2M5 TC-2O5-O2-I2M5 TC-205-02-2M5 TC-205-02-4M5 TC-205-02-6M5 TC-205-02-8M5 TC-205-02-10M5 TC-201-02-6M5 TC-201-02-8M5

Information

Overview Manuals Environmental Resilience & Safety Standards

Features:

  • I/O Companion Slot, Internal, 40 Channel Output to FTA
  • Tailored exclusively for Output Channels to interface with Trusted DO/AO modules and output FTAs
  • Industrial-grade, long-distance Output Companion Slot Cable
The Rockwell ICS Triplex TC-205-02-12M5 is a long-distance, I/O-compatible slot-out cable designed for Trusted Triple Redundancy (TMR) safety control systems. It serves as a remote connection between industrial safety master racks and field execution hardware, specifically designed to connect rack-mounted safety output modules (such as TMR digital or analog output modules) to control loops. With a physical length of up to 12.5 meters (code 12M5), this cable enables lossless transmission of drive commands and emergency protection signals to more distant field terminals (FTAs or VFTAs) compared to standard specifications, significantly improving cabling flexibility between large central control rooms and distributed field cabinets.

This long-span cable plays a crucial role in process industry safety, meeting SIL 3 (highest infrared detection level) requirements. Its applications include emergency power outages (ESD), fire and gas detection (F&G), and control of critical rotating machinery. Structurally, the cable features a 96-channel Type-C high-density connector at the control rack end for connecting the main working module and the hot standby module; and two 96-channel Type-R connectors at the field end for connecting field application transmissions (FTAs).

The TC-205-02-12M5 ICS Triplex Trusted I/O Companion Slot Cable Assembly may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
ICS Triplex TC-205-02-12M5 Trusted I/O Companion Slot Cable Assembly MANUAL(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
1.Flame-retardant construction: The cable outer sheath is made of high-quality low-smoke halogen-free (LS0H/LSLH) material, strictly complying with the international IEC 60332-3 Class A flame-retardant test standard. This means that in the event of an accidental fire in a factory, the cable can effectively suppress the emission of toxic fumes and corrosive gases, thereby protecting personnel and electronic equipment in the control room.
 
2.Advanced EMI/RFI shielding: The cable is equipped with a high-density braided shielding mesh, a dedicated grounding braided tail at the chassis end, and a green grounding wire at the field end. This design prevents environmental electromagnetic noise from interfering with critical control circuits operating near high-voltage motor starters or switchgear.
 
3.Critical protection circuitry: In high-risk process industries such as oil and gas refining, petrochemical processing, and chemical production, automatic emergency stop (ESD), burner management system (BMS), and fire and gas (F&G) mitigation circuits rely on this.

Technical notes

The Rockwell Automation TC-205-02-12M5 is a 12.5-meter, 40-channel output I/O side-mount cable designed for Trusted TMR systems. Its core utilizes a three-core composite structure. The rack end features dual 96-pin C-type connectors for shunting high-density signals; the field end integrates a 96-pin R-type connector and a power connector. The cable is made of low-smoke halogen-free (LSZH) material conforming to IEC 60332-3 Class A flame-retardant standards, ensuring high immunity and physical safety.
  • Product Lifecycle Stage

    Active/Available from OEM

    The ICS Triplex TC-205-02-12M5 is currently available for sale and is suitable for industrial safety and control applications. Moore Automated provides high-quality ICS Triplex replacement modules and spare parts, offering reliable and cost-effective solutions that help minimize downtime and ensure the reliable operation of critical systems.

Ask our team:

  • How does the cable length of the TC-205-02-12M5 differ from other cable assemblies?
    The TC-205-02-12M5 has a cable length of 12.5 meters, making it particularly suitable for industrial applications where the distance between the proximity probe and the monitoring electronics is large. The factory-preset 12.5-meter cable length helps maintain the calibration characteristics of the entire sensor system.
  • How does the TC-205-02-12M5 maintain excellent signal integrity during high-frequency transmission?
    The TC-205-02-12M5 employs a low-capacitance coaxial cable structure, precision conductors, and advanced electromagnetic shielding technology to minimize electromagnetic interference (EMI), radio frequency interference (RFI), signal attenuation, and electrical noise. These characteristics ensure high-precision transmission of eddy current sensing signals.
  • What connector architecture does the TC-205-02-12M5 use to achieve reliable industrial connections?
    The TC-205-02-12M5 comes pre-installed with precision industrial connectors designed to provide robust mechanical connections, low contact resistance, and long-term electrical reliability. This connector configuration minimizes installation complexity while maximizing operational stability.
  • What are the electrical transmission characteristics of the TC-205-02-12M5?
    The TC-205-02-12M5 features stable characteristic impedance, low insertion loss, excellent shielding effectiveness, and a superior signal-to-noise ratio. These electrical characteristics ensure the accuracy, linearity, and repeatability of the entire mechanical condition monitoring system.
  • In which industrial sectors is TC-205-02-12M5 typically used?
    TC-205-02-12M5 is widely used in steam turbines, gas turbines, centrifugal compressors, generators, electric motors, pumps, fans, blowers, industrial gearboxes, and other rotating equipment. In these applications, long-distance, low-noise signal transmission is crucial for machinery protection and condition monitoring.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.