TC-311-02

Local Expansion Cable Assembly, 1 way (2m)
In Stock
Ships by Thursday, August 27
Fast Shipping Available

Product Information:

The TC-311-02 is a high-reliability unidirectional local extension cable assembly (1-way) developed by Rockwell Automation's ICS Triplex specifically for trusted critical control and safety systems. As a hardware link for extending control network topologies, it primarily enables point-to-point and multi-point high-speed interconnection between the T8311 extension interface module in the trusted controller chassis and the T8310 triple-redundant extension processor in the extender chassis, ensuring efficient and secure cross-chassis data flow.

The TC-311-02 uses high-standard industrial-grade materials, providing safety protection and environmental adaptability. The suffix "02" in the model number indicates that its outer sheath is made of low-smoke halogen-free (LSZH) flame-retardant material. This material not only meets the stringent requirements of the IEC 60332-3 Class A flame-retardant standard but also does not release toxic halogen gases in the event of a fire.

Furthermore, the TC-311-02 features a robust electromagnetic shielding layer and low-latency transmission characteristics, completely eliminating signal distortion or false triggering caused by hardware-level noise interference or media aging. In practical industrial applications, this cable is an indispensable communication link for building large-scale, multi-rack SIL 3 fault-tolerant safety control systems.

Expand All
Collapse all

Technical specifications for TC-311-02

  • Manufacturer:
    ICS Triplex
  • Product Category:
    Safety Automation
  • Spare Part Number:
    TC-311-02
  • Estimated shipping dimensions:
    10.2 x 11.89 x 18.6 cm
  • Weight:
    0.21 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Cable type:
    TC-311-02 local expansion cable assembly, 1-way
  • Function:
    Connects Trusted Expander Interface Module T8311 to Trusted TMR Expander Processor T8310
  • Insulation code:
    02: low-smoke zero-halogen, flame-retardant to IEC 60332-3 Category A
  • Connector arrangement:
    96-way type C connector in a double-width hood with earth braid at T8310 end; 12-way LEMO plug at T8311 end
  • Cable family:
    Trusted communications cable
  • Stock:
    15

Alternative Names

TC 311 02 TC31102 TC-3II-02 TC-311-O2 TC-3II-O2 TC-311-03 TC-312-02 TC-312-03 TC-313-02 TC-313-03 TC-311-02/03 TC-312-02/03 TC-313-02/03

Information

Overview Manuals Application Scenarios

Features:

  • Local Expansion Cable Assembly, 1 way
  • From Expander Interface Module (T8311) to Triple Modular Redundant (TMR) Expander Processor (T8310)
  • Trusted Communications Cables
The ICS Triplex TC-311-02 is a high-reliability unidirectional local extension cable assembly (1-way) designed for critical safety control systems. As a dedicated component for Rockwell Automation's Trusted Triple Modular Redundancy (TMR) control system, it primarily enables direct communication between the T8311 extender interface module and the T8310 extender processor.

This cable ensures seamless, microsecond-level synchronous transmission of input/output (I/O) data and control commands between the master and extender base stations by providing a high-bandwidth, deterministic data path. Furthermore, the component offers superior fault tolerance and industrial-grade durability. Its cable physical structure effectively resists high-frequency electromagnetic interference (EMI) and radio frequency interference (RFI), and it is designed for uninterrupted operation of safety instrumented systems (SIS).

The TC-311-02 ICS Triplex Local Expansion Cable Assembly, 1 way (2m) may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
ICS Triplex TC-311-02 Local Expansion Cable Assembly, 1 way (2m) Manuals(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
1. Chassis-to-Chassis Bus Expansion:
 
Main Rack to Expansion Rack Connection: The primary purpose of the TC-311-02 is to connect the T8311 Trusted Extender Interface Module (located within the main controller chassis) to the T8310 Extender Processor Module (located within the extender chassis).
Multi-point Distributed I/O: It enables the main controller processor to communicate deterministically with remote or additional input/output (I/O) chassis via a local high-speed bus, achieving seamless system expansion.
 
2. SIL 3 Safety Applications:

Because this cable retains the fully redundant architecture of the Trusted Platform, it is typically suitable for systems requiring SIL 3 (Safety Integrity Level 3) certification.
Core industrial loop applications include: Emergency Stop (ESD) Systems: Connecting auxiliary I/O chassis containing safety-critical field trip valves and emergency disconnect switches.
Fire and Gas (F&G) Systems: Suitable for large-scale multi-chassis deployments requiring connection of numerous fire, gas, and smoke detectors to the central processing unit.
Burner Management System (BMS): Used in expander links within complex boiler or furnace environments where absolute time control and fault isolation are essential.
 
3. Enclosed and Fire-Sensitive Environments The specific "-02" designation indicates a Low Smoke Halogen-Free (LSZH) enclosure. This directly determines its application in specific harsh or confined physical spaces:
 
Offshore Platforms and Ships: Deployed in locations where toxic gas emissions during a fire would pose a significant hazard to personnel within the enclosed control room.
Petrochemical and Refinery Control Rooms: Used for sealed control rooms to meet international plant fire safety standards (e.g., IEC 60332-3 Class A).
Power Plant and Nuclear Power Control Systems: Used in locations with high levels of electromagnetic interference (EMI); its thick internal shielding protects critical extended data from interference from adjacent high-voltage lines.

Technical notes

Official Rockwell Automation publication ICSTT-RM312N-EN-P Issue 17 verified for TC-311-02. Use the complete order code; do not substitute a different insulation suffix, cable family or length. Installation must follow the manufacturer manual.
  • Product Lifecycle Stage

    Active/Available from OEM

    Moore Automated provides high-quality ICS Triplex replacement modules, communication cables, and spare parts for Trusted security systems. Our reliable and cost-effective solutions help reduce unplanned downtime, extend equipment life, and ensure continuous reliable plant operation.

Ask our team:

  • What is the Rockwell Trusted TC-311-02?
    Rockwell Automation identifies TC-311-02 as a Trusted Communications Cable, specifically a Local Expansion Cable Assembly, 1 way. Official source: https://literature.rockwellautomation.com/idc/groups/literature/documents/rm/icstt-rm312_-en-p.pdf
  • Which Trusted modules does TC-311-02 connect?
    Rockwell specifies the TC-311-02 local expansion assembly for the connection from a Trusted Expander Interface Module (T8311) to a Trusted TMR Expander Processor (T8310).
  • What does the “1 way” designation mean for TC-311-02?
    Rockwell’s cable table identifies TC-311-02 as the one-way Local Expansion Cable Assembly used in the multi-drop connection between T8311 expander interface modules and T8310 processors.
  • What cable construction is specified for the -02 version?
    Rockwell specifies the -02 version as a screened LSZH cable construction; the -03 alternative is the UL-certified version.
  • What element length is shown for the TC-311 assembly?
    Rockwell’s assembly example for TC-311-02/0 shows one cable element from SKT1 to SKT2 with a 2m0 length. Confirm the supplied configuration before installation.
  • What electrical limits are stated for Trusted cable assemblies?
    Rockwell’s official certificate states a maximum working voltage of 60 V and a maximum current of 2 A per channel for the covered cable assemblies. Official source: https://literature.rockwellautomation.com/idc/groups/literature/documents/ct/icstt-ct013_-en-e.pdf
  • What routing rule does Rockwell give for TC-311 cables?
    Rockwell recommends avoiding lateral strain and tight bends; the bend radius should not be less than four times the cable diameter, and the cable should run parallel to the connector for at least 100 mm before bending.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.