ICS Triplex TC-501-02-8M5
ICS Triplex TC-501-02-8M5
· Product image is representative; revision or series may vary. Contact us to request a specific version.

TC-501-02-8M5

I/O SmartSlot, Internal, 40 Channel Input to FTA, 8.5m
In Stock
Ships by Thursday, August 27
Fast Shipping Available

Product Information:

The TC-501-02-8M5 is a SmartSlot input signal connection cable from Rockwell Automation's ICS Triplex Trusted series, designed specifically for triple redundancy (TMR) industrial safety control systems. This model is suitable for high-density industrial safety loops, stably transmitting up to 40 analog or digital input signals. It provides a highly reliable hardware connection between input modules (such as T8403, T8431, etc.) and field terminals (FTAs) within a Trusted system.

The core manufacturing process and physical specifications of the TC-501-02-8M5 are determined by its suffix code. "-02" indicates that the cable's outer insulation sheath is made of low-smoke halogen-free (LSZH/halogen-free) material, offering extremely high flame-retardant properties. Even in the event of a fire, it will not release dense smoke or corrosive toxic gases, fully complying with the highest level of industrial fire safety standards. "-8M5" precisely defines the cable's physical length as 8.5 meters.

In practical industrial applications, the TC-501-02-8M5 cable features a robust 96-pin "C" type DIN industrial connector and a dedicated shielded grounding wire, offering superior electromagnetic interference (EMI) immunity and resistance to industrial vibration. With its exceptionally long 8.5-meter span, this cable is widely used in large central control rooms or emergency shutdown (ESD) and fire and gas monitoring (F&G) systems, and can also be used for cabling between server racks. As a critical infrastructure component, it ensures the safety of assets and personnel in high-risk facilities such as offshore oil platforms, refineries, and nuclear power plants.

Expand All
Collapse all

Technical specifications for TC-501-02-8M5

  • Manufacturer:
    ICS Triplex
  • Product Category:
    Safety Automation
  • Spare Part Number:
    TC-501-02-8M5
  • Estimated shipping dimensions:
    10.2 x 11.5 x 16 cm
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Cable type:
    TC-501-02 I/O SmartSlot V2 internal 40-channel input cable to FTA
  • Function:
    Connects analogue or digital input signals from an internal FTA to the Trusted input module
  • Specified length:
    8.5 m
  • Insulation code:
    02: low-smoke zero-halogen, flame-retardant to IEC 60332-3 Category A
  • Connector arrangement:
    96-way type C connector at chassis end; 96-way type R connector at FTA end
  • Cable construction:
    Multi-core cable stripped back 1.5 m at both ends and shrouded in nylon Rilgain sheath
  • Maximum recommended I/O cable length:
    15 m
  • Stock:
    12

Alternative Names

TC501028M5 TC 501 02 8M5 TC-5O1-O2-8M5 TC-50I-02-8M5 TC-501-02-BM5 TC-5OI-O2-BM5 TC-501-02-2M5 TC-501-02-4M5 TC-501-02-6M5 TC-501-02-10M5 TC-501-02-12M5 TC-501-02-2M0

Information

Overview Manuals Application Cases Certifications & Standards

Features:

  • I/O SmartSlot V2 Internal 40 Channel Input to FTA
  • Specifies an Internal 40-Channel Input SmartSlot Cable
  • Designates a Low-Smoke Zero-Halogen (LSZH) fire-retardant outer insulation jacket
The TC-501-02-8M5 is a high-reliability Trusted I/O SmartSlot cable from Rockwell Automation's ICS Triplex brand. This 8.5-meter cable (the "8M5" at the end of the model number indicates its length) is designed for critical safety and high availability applications. Its primary function is to provide a high-density physical signal transmission link over ultra-long distances, enabling high-speed, stable electrical connections between Trusted Triple Modular Redundancy (TMR) input/output modules and field terminal blocks (FTA/VFTA) or spare rack slots with pre-processed terminals, ensuring seamless interconnection of industrial control signals.

Furthermore, this cable features excellent industrial-grade physical protection and electromagnetic compatibility. To withstand extremely harsh industrial environments, it utilizes an abrasion-resistant, oil-resistant nylon braided sheath and heat-sealed ends, effectively resisting harness wear caused by high-frequency industrial vibration and mechanical friction. Meanwhile, the cable integrates a full-coverage braided shielding mesh and is equipped with a dedicated green grounding lightning protection shielding wire, which can isolate complex external electromagnetic interference (EMI/RFI) to the maximum extent and ensure zero distortion of critical safety control data transmission.

The TC-501-02-8M5 ICS Triplex I/O SmartSlot, Internal, 40 Channel Input to FTA, 8.5m may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
ICS Triplex TC-501-02-8M5 I/O SmartSlot, Internal, 40 Channel Input to FTA, 8.5m Manuals(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
1. Rack-Top Cross-Rack Cabling:
 
In large industrial control rooms, safety processors and field cabling assemblies (FTAs) are typically designed with isolation to prevent overheating and simplify loops.
Scenario: The primary trusted TMR processor chassis resides within a central "processor control rack," while field instruments connect to terminal blocks in separate "junction boxes."
Application Example: An 8.5-meter cable allows automation engineers to run a 40-channel input harness from the processor cabinet up through a rack-top cable tray (ladder rack), across control room aisles, and finally to the junction box without creating structural cable tension.
 
2. Offshore Platform and Ship Safety Loops:

Space is extremely limited on offshore oil platforms and floating production storage and offloading (FPSO) vessels, meaning safety systems must be tightly fitted within bulkheads and enclosed modules.
Scenario: Rapid, automated platform shutdown is required in the event of a fire or gas leak.
Application Example: Low-smoke halogen-free (-02) conduit racks are explicitly used here. In the event of an electrical fire causing cable tray rupture, the 8.5-meter-long conduit rack prevents the release of glaring black smoke or toxic acidic halogens (such as hydrogen chloride) into enclosed living areas or evacuation routes, ensuring unobstructed evacuation routes [V1].
 
3. Remote Area Toxic and Combustible Gas Monitoring (F&G) Refineries and chemical plants operate extensive perimeter safety loops to detect toxic gases such as volatile organic compounds (VOCs) or hydrogen sulfide (H₂S).
 
Scenario: Dozens of remote gas detectors simultaneously issue activation status signals.
Application Example: The TC-501-02-8M5 can transmit critical analog/digital input signals from up to 40 channels to a safety rack via its 8.5-meter-long line. Its integrated high-strength nylon braided layer and green shielded grounding wire protect sensitive 4-20mA monitoring signals from severe electromagnetic interference (EMI) generated by nearby high-voltage plant motors or switchgear.
 
4. Burner Management System (BMS) in Power Facilities: Industrial boilers, pyrolysis units, and utility furnaces operate under extreme temperatures, requiring continuous flame and pressure diagnostics to prevent catastrophic explosions.
 
Application Scenario: Continuous monitoring of rapid emergency trip lines and achieving zero communication latency are critical.
Application Example: This cable directly maps field flame scanners and boiler fuel trip valves to reliable safety logic. The 8.5-meter transmission distance ensures that sensitive electronic control boxes can be placed at a safe distance from radiant heat sources on the boiler casing.
1.IEC 60332-3 Class A: Certified with high-level vertical flame retardancy. This test ensures that an 8.5-meter cable will not spread fire vertically along cabinet bundles or cable tray layouts.
2.Low Smoke Halogen-Free (LSZH): Material-certified to be completely halogen-free. Certified to limit smoke concentration and completely prevent the release of toxic, highly corrosive halogen acid gases (e.g., hydrogen chloride) under fire conditions.
3.EC 61508 (SIL 3): Although the cable is a passive mechanical transmission element, the TC-501 assembly is certified as a foundational component of the broader TÜV-certified Trusted TMR platform. It is fully authorized to maintain loop and signal integrity in safety-critical infrastructure at Safety Integrity Level 3 (SIL 3).
4.ATEX Directive/IECEx: Certified for spark-free deployment in Zone 2/Class I Zone 2 hazardous industrial locations, provided it is fully installed in a protective control cabinet conforming to the corresponding ratings.
5.CE/UKCA Certification: Officially certified to comply with the EU and UK safety, health, and environmental protection frameworks.
6.ABS (American Bureau of Shipping) and DNV (Det Norske Veritas): Verified to withstand vibration, marine humidity, and thermal cycling under continuous operating pressure.

Technical notes

Official Rockwell Automation publication ICSTT-RM313Q-EN-P Issue 19 verified for TC-501-02-8M5. Use the complete order code; do not substitute a different insulation suffix, cable family or length. Installation must follow the manufacturer manual.
  • Product Lifecycle Stage

    Obsolete/Discontinued by OEM

    The recommended replacement and upgrade is the ICS Triplex Trusted® TMR series, which offers enhanced processing performance, advanced diagnostics, and long-term support for existing ICS Triplex applications. Moore Automated provides high-quality ICS Triplex replacement modules and spare parts, including reliable alternatives to the TC-501-02-8M5. Our cost-effective solutions help reduce unplanned downtime, extend the life of existing control systems, and ensure continued reliable industrial performance.

Ask our team:

  • What is the Rockwell Trusted TC-501-02-8M5?
    Rockwell Automation identifies TC-501-02-xmx as an I/O SmartSlot V2 internal 40-channel input cable to an FTA. The exact -8M5 configuration uses the specified 8.5 m length. Official source: https://literature.rockwellautomation.com/idc/groups/literature/documents/rm/icstt-rm313_-en-p.pdf
  • What signals does TC-501-02-8M5 carry?
    Rockwell specifies TC-501 for analogue or digital input modules and for connecting input signals from an internal FTA to the module.
  • What connectors are specified for TC-501?
    Rockwell specifies a 96-way type C connector at the chassis end and a 96-way type R connector at the other end for connection to an FTA.
  • What does the 8M5 suffix indicate?
    Rockwell states that SmartSlot cable length is specified to the nearest 0.5 m in xmx format; 8M5 denotes the 8.5 m configuration.
  • What does the -02 insulation code indicate?
    Rockwell states that 02 denotes Low Smoke Zero Halogen (LSZH) cable material and that it is flame retardant to IEC 60332-3 Cat A.
  • What maximum cable length does Rockwell recommend for SmartSlot I/O cables?
    Rockwell recommends a maximum I/O cable length of 15 m; longer cables may experience voltage drop, offset, crosstalk and noise.
  • Which module and FTA families are shown with TC-501?
    Rockwell’s TC-501 diagram lists modules including T8403, T8423, T8425 and T8431, and FTAs including T8800, T8801, T8821, T8825 and T8830/1. Verify the installed configuration before ordering.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.