T9110

Processor module
In Stock
Ships by Tuesday, June 23
Fast Shipping Available

Product Information:

T9110 refers to the Rockwell Automation/ICS Triplex AADvance T9110 processor module. As the central processing unit (CPU) of the AADvance safety controller system, it executes critical safety application logic, manages the controller I/O network, handles faults, and enables secure industrial control communication.

This module also features comprehensive electrical isolation, dual redundant 24V DC power supplies, and real-time hardware self-diagnostic mechanisms. It enables channel fault isolation and seamless failover without interrupting critical control and network communications, thus ensuring continuous and stable operation for safety-related applications such as emergency power outages (ESD) and gas control.

Expand All
Collapse all

Technical specifications for T9110

  • Manufacturer:
    ICS Triplex
  • Product Category:
    PLC System
  • Estimated shipping dimensions:
    4.1x12.5x16.5cm
  • Weight:
    0.44 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Voltage Range (Vdc):
    18-32 VDC
  • Maximum Current (mA):
    380 mA
  • Product Type:
    Processor Module
  • Ambient temperature range:
    -25 °C to +60 °C (-13 °F to +140 °F)
  • Power Consumption:
    8.0 W
  • Module Power Heat Dissipation:
    8.0 W (27.3 BTU/hr.)
  • Category Series:
    Trusted TMR System
  • Stock:
    120

Alternative Names

T9II0 T911O T9300 T9310 T9401/2 T9431/2 T9451 T9481/2 T9401 T9402

Information

Overview Manuals Principle Primary Applications

Features:

  • Programmable Logic Controllers CPU Models
  • ICS Triplex AADvance controller system
  • It is a high-performance, fault-tolerant CPU designed specifically for safety-critical industrial applications
The AADvance system consists of the AADvance controller, external operator workstations, field connections, power supply, and external network connectivity. Its flexible design allows it to meet a variety of business needs.

The AADvance controller is designed for functional safety and critical control applications, providing a flexible solution for small-scale applications. The system can also be used for safety functions, as well as applications that are not safety-related but critical to business processes. The AADvance controller is particularly suitable for emergency shutdown, fire, and gas detection and protection applications because it provides a system solution with integrated distributed fault tolerance.

The T9110 ICS triplex Processor module may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
ICS Triplex T9110 Processor module maunal(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The controller is designed and validated according to international standards and is certified by independent certification bodies for functional safety control devices and by UL for hazardous environments. The controller consists of a series of compact, plug-in modules that are easy to assemble into a system. A system can include one or more controllers, along with combinations of I/O modules, power supplies, communication networks, and user workstations.
Safety Instrumented Systems (SIS): Serving as the core CPU of high-risk process systems, managing processes where failure could lead to environmental damage or personal injury.
Emergency Shutdown (ESD): Used in the oil, gas, and chemical industries to immediately isolate or disconnect equipment power upon detection of hazardous process conditions.
Fire and Gas (F&G) Detection: Processes data from flame and toxic gas sensors to automatically trigger fire suppression systems, dampers, and audible and visual alarms.
Boiler Management System (BMS): Manages the complex startup procedures, fuel isolation, and flame monitoring of industrial boilers and furnaces.
High Integrity Pressure Protection System (HIPPS): Provides ultra-fast isolation of high-pressure sources to protect downstream piping and vessels.

Technical notes

The T9110 processor module is a high-reliability safety controller core designed specifically for high-risk industrial environments. It utilizes a 400 MHz processor and a robust embedded safety core, supporting various fault-tolerant degradation architectures such as 1oo1D, 1oo2D, and 2oo3D (triple module redundancy/TMR). In single-module mode, it achieves SIL1 industrial safety level; in multi-module redundancy mode, it achieves SIL3 industrial safety level.

Ask our team:

  • How does T9110 implement fault-tolerant processing strategies to achieve high safety integrity levels?
    The T9110 utilizes redundant processing pathways, continuous self-diagnostics, and cross-monitoring mechanisms to detect latent faults and ensure safe operational continuity in accordance with IEC 61508 principles.
  • Why is T9110 considered suitable for mission-critical and high-availability safety instrumented systems (SIS)?
    The T9110 is engineered with deterministic execution cycles, rigorous error detection, and predictable fail-safe behavior, making it appropriate for applications requiring SIL-rated protection.
  • In what manner does T9110 coordinate with distributed I/O modules to preserve signal integrity and temporal determinism?
    The T9110 communicates over the system backplane and internal buses using synchronized data exchange protocols, ensuring coherent processing of safety-related input and output signals.
  • How does T9110 facilitate lifecycle management and configuration control within safety-regulated environments?
    The T9110 supports structured configuration, version traceability, and controlled firmware management to maintain compliance throughout the safety lifecycle.
  • What diagnostic granularity is embedded within T9110 to enhance fault transparency and proof-testing efficiency?
    The T9110 continuously performs self-monitoring of processing elements, memory integrity, and communication channels, providing detailed diagnostic feedback to expedite troubleshooting and validation.
  • To what extent does T9110 support redundancy and system scalability within complex automation infrastructures?
    The T9110 enables scalable deployment through modular expansion and supports redundant configurations to enhance system availability and fault containment.
  • In which high-risk industrial sectors does T9110 deliver the most substantial safety and operational value?
    The T9110 is particularly suited for oil & gas, chemical processing, power generation, and other hazardous industries where robust safety logic execution and high system integrity are paramount.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.