140NOE77111

Ethernet Network TCP/IP Module
In Stock

Product Information:

140NOE77111 Product Schneider Electric

Ethernet network TCP/IP module, Modicon

Quantum, transparent ready,

750mA at 5VDC, class C30

Expand All
Collapse all

Technical specifications for 140NOE77111

  • Manufacturer:
    Schneider Electric
  • Product Category:
    PLC System
  • Estimated shipping dimensions:
    31.5x16.5x4.7cm
  • Weight:
    0.499 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    France
  • Place of shipment:
    Xiamen, Fujian, China
  • Current consumption:
    750 mA 5 V DC
  • IP degree of protection:
    IP20
  • Product certifications:
    CUL UL 508
  • Resistance to electrostatic:
    discharge 4 kV contact IEC 801-2 8 kV on air IEC 801-2
  • Resistance to electromagnetic fields:
    10 V/m 80...1000 MHz IEC 801-3
  • Ambient air temperature for operation:
    0...60 °C
  • Ambient air temperature for storage:
    -40...85 °C
  • Relative humidity:
    95 % without condensation
  • Stock:
    30

Information

Overview Manuals Working Principle Target Industries

Features:

  • Ethernet network TCP/IP module
  • Modicon Quantum automation platform
  • Transparent ready, 750mA at 5VDC, class C30
Primarily used for high-speed data exchange and network interconnection between industrial automation systems and Supervisory Control and Data Acquisition (SCADA) systems. As a network interface unit for PLCs, this module can publish process data, status information, and diagnostic data from within the controller via industrial Ethernet, thereby achieving transparent communication between the control and monitoring layers.

Its design emphasizes high-bandwidth communication capabilities and industrial-grade reliability, enabling stable operation in complex network environments and supporting multi-node device access, thus improving the overall scalability and information integration capabilities of the system.

The 140NOE77111 Schneider Electric Ethernet Network TCP/IP Module may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Schneider Electric 140NOE77111 Ethernet Network TCP/IP Module Manuals(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The 140NOE77111 operates based on the data encapsulation and forwarding mechanism of the industrial Ethernet protocol stack. This module, through its built-in network processing unit, maps the PLC's internal data to the communication register area, encapsulates the data according to standard protocols such as TCP/IP, and then sends it to network nodes. Simultaneously, it continuously monitors access requests from the host system, parses read and write instructions, and maps them to the PLC memory, thereby achieving bidirectional data interaction. This process relies on real-time network protocol processing, data buffering mechanisms, and communication task scheduling to ensure stable, efficient, and reliable data communication in industrial network environments.
This module is widely used in large infrastructure and process industries, including:
 
  1. Water treatment and petrochemicals: Long-distance fiber optic communication and remote diagnostics are crucial in these industries.
  2. Energy and mining: Provides reliable, redundant networks for critical power and mining systems.
  3. Infrastructure: Enables powerful automated control in fields such as airport systems, tunnels, and metallurgy.

Ask our team:

  • How does the 140NOE77111 facilitate deterministic industrial communication in Ethernet networks?
    The 140NOE77111 implements optimized TCP/IP-based communication services, ensuring structured data exchange between PLC controllers, SCADA systems, and distributed I/O nodes, with predictable network performance.
  • Why is the 140NOE77111 crucial for monitoring and remote diagnostics in industrial automation systems?
    The 140NOE77111 supports real-time remote access to PLC memory, process variables, and diagnostic registers, enabling engineers to perform system monitoring, troubleshooting, and configuration from a centralized control station.
  • How does the 140NOE77111 support multi-protocol interoperability in industrial Ethernet environments?
    The 140NOE77111 is designed to support standard Ethernet communication protocols used in industrial automation, enabling seamless integration with SCADA, HMI, and third-party control systems.
  • What role does the 140NOE77111 play in a Distributed Control System (DCS) architecture?
    The 140NOE77111 acts as a communication gateway between the Modicon Quantum CPU and higher-level monitoring systems, enabling hierarchical data exchange within the distributed automation infrastructure.
  • How does the 140NOE77111 enhance network scalability and system scalability?
    The 140NOE77111 allows additional PLC nodes and remote devices to be integrated into existing Ethernet networks without major architectural redesign, thus supporting modular system expansion.
  • Why is Ethernet-based communication advantageous in the design of the 140NOE77111?
    Compared to traditional serial-based industrial networks, the 140NOE77111 leverages Ethernet infrastructure to provide high-bandwidth, flexible, and cost-effective communication.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.