CAD32MD

TeSys D control relay
In Stock

Product Information:

TeSys D control relay

3 NO + 2 NC - <= 690

V - 220 V DC standard coil

industrial automation system

Expand All
Collapse all

Technical specifications for CAD32MD

  • Manufacturer:
    Schneider Electric
  • Product Category:
    PLC System
  • Estimated shipping dimensions:
    7.7 x 4.5 x 9.3 cm
  • Weight:
    0.58 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    FRANCE
  • Place of shipment:
    Xiamen, Fujian, China
  • Pole contact composition:
    3 NO + 2 NC
  • rated operational voltage:
    <= 690 V AC 25...400 Hz
  • Control circuit type:
    DC standard
  • control circuit voltage:
    220 V DC
  • rated impulse withstand voltage:
    6 kV conforming to IEC 60947
  • conventional free air thermal current:
    10 A (at 60 °C)
  • Stock:
    20

Information

Overview Manuals Principle

Features:

  • TeSys D control relay - 3 NO + 2 NC - <= 690 V - 220 V DC standard coil
  • High-density digital input/output functionality designed specifically for industrial automation systems
  • Modular architecture with reliable electrical isolation and diagnostic monitoring support
The CAD32MD is an industrial-grade digital I/O module typically used in automation control platforms to manage discrete signals between field devices and a central controller. Its primary function is to acquire digital input signals from sensors and switches while simultaneously providing digital output control to actuators, relays, and other switching devices. This bidirectional signal processing approach enables efficient coordination between control logic and physical devices in automation systems.

In practical applications, the CAD32MD integrates multiple digital channels into a compact, modular unit, enhancing system scalability and wiring efficiency. It supports stable signal transmission and features built-in protection against electrical noise, short circuits, and voltage fluctuations. This module is commonly used in environments where reliable discrete signal management is critical, such as production lines, process control systems, and machine automation.

The CAD32MD Schneider Electric TeSys D control relay may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Schneider Electric CAD32MD TeSys D control relay Manuals(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The CAD32MD operates based on digital signal detection and controlled switching via internal electronic circuitry. Input channels detect external voltage states and convert them into logic-level signals readable by the controller, while output channels receive control commands from the system and activate corresponding switching elements to drive field loads. The CAD32MD ensures accurate and reliable operation of digital signals within industrial automation architectures through an electrically isolated interface and real-time data exchange with the host controller.

Ask our team:

  • What core functional architecture defines the operational role of CAD32MD within industrial control and power distribution systems?
    The CAD32MD is engineered as a modular electrical control or interface component designed to facilitate reliable power switching, signal routing, or load management in automation environments. Its internal architecture integrates contact-based switching mechanisms and structured connection terminals to ensure deterministic electrical control.
  • How does CAD32MD achieve reliable switching performance under high-current or inductive load conditions?
    The CAD32MD typically incorporates contact materials and arc suppression design strategies that enhance durability during repeated switching operations. Through optimized contact geometry and mechanical actuation precision, it minimizes contact wear, voltage spikes, and thermal stress when managing inductive loads.
  • Why is the modular design configuration of CAD32MD advantageous for scalable automation architectures?
    The CAD32MD is designed for standardized mounting and structured system integration. Its modular form factor allows seamless installation into control panels or distribution systems, enabling incremental expansion and simplified maintenance without redesigning the entire electrical infrastructure.
  • How does CAD32MD enhance operational reliability in environments subject to vibration, temperature variation, or electrical noise?
    The CAD32MD is typically constructed with industrial-grade materials, reinforced terminals, and secure mechanical fastening mechanisms. These design attributes reduce the risk of loose connections, contact instability, or signal disruption caused by environmental stressors.
  • How does CAD32MD maintain safe operation when controlling high-inrush or motor-starting loads?
    The CAD32MD is engineered with contact ratings and surge tolerance characteristics suitable for handling transient inrush currents. Its contact structure and electrical rating are aligned to prevent welding, overheating, or premature degradation during high-demand switching events.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.