Request a Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Tuesday, October 20
Fast Shipping Available
Nonredundant 24 VDC Sink-Output IOTA

CC-TDOD51

Product Information:

CC-TDOD51 is the nonredundant Series C IOTA used with Honeywell's CC-PDOD51 24 VDC sink-output module. The matched assembly supports 32 open-drain output channels, rated up to 0.1 A per channel, with a common return and selectable internal or external field-power arrangement. The IOTA has a nominal 9-inch size; the electronic IOM and any additional hardware must be specified separately.

  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      CC-TDOD51 provides the field-termination and mounting interface for a nonredundant Series C sink-output installation. With the specified CC-PDOD51 IOM fitted, the arrangement switches low-current 24 VDC field circuits through 32 open-drain channels. The channels share a common return and a common selected power source, so this is not a bank of independently powered dry contacts. IOTA wiring determines whether the field circuits use system power or an external supply. The distinction matters when reviewing field isolation, load suitability and spare-parts scope: the termination board is one part of the complete output assembly, not a standalone control device.

      Check sink-output and power compatibility

      Match the nonredundant CC-TDOD51 IOTA to the CC-PDOD51 IOM, the installed field-power arrangement and loads within the 100 mA channel limit. Preserve the existing wiring and output configuration; the redundant CC-TDOD61 has a different documented arrangement.
    • APPLICATIONS

      Where it may be used

      Industry examples for suitably rated low-current control circuits connected through the complete Series C sink-output assembly; the IOTA alone does not drive field equipment.

      Chemical Processing

      Commands suitably rated solenoid valves on chemical dosing skids.

      Water & Wastewater

      Switches low-current interposing relays in treatment-plant auxiliary control circuits.

      Oil & Gas

      Provides equipment-enable signals to compatible interfaces on process utility skids.

      Pulp & Paper

      Controls low-current valve interfaces on mill process-service equipment.
Technical specifications for

CC-TDOD51

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Assembly type:
    Nonredundant digital-output IOTA
  • Compatible IOM:
    CC-PDOD51, 24 VDC sink-output module
  • Nominal IOTA size:
    9 inches; not packed dimensions
  • Output channels:
    32 in the matched IOM/IOTA assembly
  • Output circuit:
    SINK / open drain; bussed common return
  • Nominal field supply:
    24 VDC
  • Maximum load voltage:
    30 VDC, published maximum
  • Maximum channel load:
    0.1 A (100 mA) per channel
  • Off-state voltage:
    24 V typical, matched output assembly
  • Off-state leakage:
    100 µA maximum
  • Turn-on / turn-off:
    10 ms maximum
  • System-field isolation:
    1000 VAC RMS with user-supplied field power
  • Field-power selection:
    Internal system supply or external supply, selected by IOTA wiring
  • Output modes:
    Latched, pulsed or pulse-width modulated, configured per IOM channel
  • Failure response:
    Hold last value or shed to configured safe value, per IOM channel
  • Overcurrent protection:
    Electronic protection in the matched output module
  • Stock Availability:
    5
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

CCTDOD51 CC TDOD51 Honeywell CC-TDOD51 IOTA

Information

Overview Manuals Sink Output Loads Field Power Selection Output Failure Modes

Features:

  • Nonredundant, nominal 9-inch termination assembly listed with the CC-PDOD51 Series C output IOM.
  • The matched output assembly provides 32 sink/open-drain channels with a maximum load of 100 mA per channel and a shared return.
  • IOTA wiring selects internal or external field power; output modes, electronic overcurrent protection and FAILOPT behavior belong to the associated IOM.

CC-TDOD51 is the nonredundant IOTA specified for Honeywell's CC-PDOD51 sink-type digital output hardware. Its job is to provide the termination and connection arrangement between the electronic module and the field circuits. The complete assembly supports 32 outputs, with a maximum channel load of 0.1 A, and is intended for compatible low-current equipment interfaces, solenoid valves and interposing relays. All outputs share a return and a selected field-power source, which must be considered when assigning circuits and reviewing the installation.

The field supply may come from the Series C system or an externally connected 24 V source, as determined by the IOTA wiring arrangement. Honeywell's 1000 VAC RMS system-to-field isolation rating is qualified by the use of user-supplied field power; it must not be presented as independent isolation between every output. The associated IOM provides configurable latched, pulsed or pulse-width-modulated operation and a channel failure response. Before replacement, record the power-selection wiring and output configuration, confirm the actual load currents, and test the affected equipment commands under the approved site procedure.

The CC-TDOD51 Honeywell Nonredundant 24 VDC Sink-Output IOTA may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Honeywell CC-TDOD51 documentation and reference links.Important Notice: This two-page excerpt retains the original Honeywell cover and page 38, which names CC-TDOD51 and gives the matched CC-PDOD51 output specification. Use the complete applicable installation manual for terminal assignments and servicing. The zero-gap switchover entry applies only to redundant configurations.

The matched assembly uses sink/open-drain outputs rather than sourcing outputs or isolated relay contacts. Each channel is limited to 0.1 A, with a published maximum load voltage of 30 VDC. Check the receiving interface and load current, including its operating characteristics, before connection. The nominal 24 VDC description does not mean that an arbitrary 24 V solenoid or contactor can be driven directly.

All outputs use a common return and the same selected source. The IOTA wiring option determines whether the circuits are referenced to the internal Series C supply or to an external field supply. Honeywell specifies 1000 VAC RMS system-to-field isolation when user-supplied field power is used. Preserve the approved supply and return arrangement; do not describe the channels as mutually isolated.

The associated Series C IOM supports a per-channel FAILOPT selection: retain the last commanded value or shed to a user-configured safe value. Latched, pulsed and pulse-width-modulated modes are also channel settings. These functions require the matched electronic module and control configuration; they are not processing features inside the bare IOTA and do not by themselves establish a safety-rated function.

Technical notes

Honeywell EP03-490-520, Release 520, version 1.5, December 2021, page 38 identifies CC-TDOD51 as the nonredundant 9-inch IOTA for CC-PDOD51. Published electrical values describe the matched output assembly. The system-to-field isolation figure requires user-supplied field power, and the zero-current-gap switchover statement is limited to redundant configurations, not this nonredundant IOTA.

Load Current and Off-State Behavior

Evaluate each field circuit against the 100 mA maximum channel load and the 30 VDC maximum load voltage. Honeywell lists a typical off-state voltage of 24 V and a maximum off-state leakage current of 100 µA, so a sensitive receiving device must be checked for the required off-state behavior. The outputs share a return and are not voltage-free contacts. Where an interposing device is used, verify that its input is compatible with sink/open-drain switching and remains within the documented electrical limits.

Channel Timing and Configuration

The published maximum turn-on and turn-off time is 10 ms for the matched output hardware. This figure does not establish the total response time of a controller program, network, actuator or process. Preserve the required latched, pulsed or pulse-width-modulated channel mode and review whether loss of control should hold the last value or shed to a configured safe value. After changing the IOTA or reconnecting field wiring, verify the selected power source and test each affected command and de-energized state using the approved commissioning procedure.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    Honeywell identifies a nominal 9-inch IOTA size. It is not the packed length, width and height; final dimensions are recorded after board and connector protection is applied.
  • Packed shipping weight
    Confirmed after final packing
    The reviewed exact-model specification does not give a verified IOTA net weight. Final gross shipping weight is measured after protective packing.
  • HS / customs code
    853890 (indicative)
    Indicative six-digit heading for a part used with electrical-control apparatus. The destination customs declarant confirms the final tariff classification for the supplied assembly.
  • Country of origin
    Confirm from supplied item
    Origin is recorded from the supplied item's official marking or traceable Honeywell documentation, not inferred from the brand or dispatch location.
  • Ships from
    Xiamen, Fujian, China
    Dispatch location, available quantity and handling time are confirmed in the quotation.
  • Customs documents
    Confirmed for the destination
    Invoice, packing-list and any required origin-document details are agreed with the order.
PRODUCT & ORDER FAQS

Questions buyers ask about CC-TDOD51

  • What is CC-TDOD51?

    It is the nonredundant 9-inch Series C digital-output IOTA listed for the CC-PDOD51 electronic module. The IOTA provides termination and connection hardware; it is not a standalone controller or output-processing module.
  • Which output module is required?

    Honeywell specifies CC-PDOD51 for this sink-output arrangement. Confirm whether the quotation includes only the IOTA or also the electronic IOM and other hardware. The redundant CC-TDOD61 is a different arrangement, not an assumed direct substitute.
  • What are the channel and load limits?

    The matched assembly has 32 sink/open-drain outputs, each limited to 0.1 A, with a published maximum load voltage of 30 VDC. All outputs share a common return. These are not independently isolated dry contacts.
  • Where can the assembly be used?

    Suitable examples include low-current solenoid and relay-interface commands on chemical skids, treatment-plant auxiliary circuits, oil-and-gas utility equipment and paper-mill services. Each actual load must be compatible with the sink output and its current limit.
  • What must installation checks include?

    Verify the IOM pairing, field-power selection, return wiring, load current, channel operating mode and configured failure response. Qualified personnel should follow the applicable Honeywell installation instructions and test affected circuits under the site's approved procedure.
  • Is CC-TDOD51 available from stock?

    The page shows the listed stock quantity. Request written confirmation of allocation, supplied condition and actual assembly marking; the displayed quantity does not reserve a specific unit.
  • What warranty is offered?

    Moore Automated offers a one-year warranty. The written quotation confirms supplied condition, coverage, start date and the return procedure before purchase.
  • How is shipment information confirmed?

    The assembly is packed with antistatic and protective materials appropriate to the supplied item. Final packed dimensions, gross weight, dispatch timing and destination documents are confirmed for the shipment; origin requires supplied-item evidence.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    CC-TDOD51 is listed in Honeywell's December 2021 Series C specification. A current exact-model OEM lifecycle notice has not been verified, so this page does not assign an active, discontinued or end-of-support status from the historical document alone.

    Moore Automated confirms actual stock allocation, assembly marking and supplied condition in the quotation. CC-TDOD61 is the separately documented redundant IOTA, not an asserted drop-in replacement; any change of arrangement requires an engineering review of the IOM, termination and field wiring.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

CC-TDOD51
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.