Request a Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
Honeywell FX-USI-0002 V1.0
Honeywell FX-USI-0002 V1.0
Honeywell FX-USI-0002 V1.0
Honeywell FX-USI-0002 V1.0
Honeywell FX-USI-0002 V1.0
Honeywell FX-USI-0002 V1.0
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Safety Interface Module

FX-USI-0002 V1.0

Spare Part Number

PNFX-USI-0002 V1.0

Product Information:

Safety Manager System Module 5 Vdc

SAFETY INTERFACE MODULE

USI-0002 Universal Safety Interface

industrial automation system

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
Technical specifications for

FX-USI-0002 V1.0

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Honeywell
  • Product Category:
    ESD System
  • Spare Part Number:
    FX-USI-0002 V1.0
  • Estimated shipping dimensions:
    17.6 × 3.52 × 21.2 cm
  • Weight:
    0.7 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Power 5 V supply voltage:
    5 V DC ± 5%
  • Power 5 V supply current:
    max 1.2A
  • Approvals:
    CE, TUV, UL, CSA, FM
  • Operating temperature:
    -5°C - +70°C (+23°F - +158°F)
  • Storage temperature:
    -40°C - +85°C (-40°F - +185°F)
  • Relative humidity:
    10 - 95% (non condensing)
  • Product Type:
    Interface Module
  • Category Series:
    Safety Manager system
  • Series:
    Honeywell Safety Systems
  • Stock:
    20
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The part is inspected, tested and securely packed before dispatch, with tracking provided after release.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

FXUSI0002V10 FX USI 0002 V1.0

Information

Overview Manuals Upgrade Advisory Integration & Usage

Features:

  • SAFETY INTERFACE MODULE Safety Manager System Module
  • USI-0002 Universal Safety Interface
  • It is a high-integrity communication and interface component
  • Used in industrial safety applications such as emergency stop (ESD) systems and fire/gas protection
The FX-USI-0002 module can be used as a spare for the FE-USI-0002, FC-USI-0002, and FC-USI-0001 modules and can replace these modules online with identical functionality. The FX-USI-0002 module can work with other FE-USI-0002, FC-USI-0002, and FC-USI-0001 modules in a redundant SM controller. The FX-USI-0002 module is only compatible with Safety Manager software version R140.1 and later.

The FX-USI-0002 module has some enhancements, but these enhancements are not activated when it is used as a replacement for the FC-USI-0001 module. These enhancements are available in Safety Manager R151.1 and later. System configuration updates for module type USI-0002 can be performed online.

The FX-USI-0002 V1.0 Honeywell Safety Interface Module may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Honeywell FX-USI-0002 V1.0 Safety Interface Module Manuals(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The FX-USI-0002 module is pin- and functionally compatible with the FE-USI-0002, FC-USI-0002, and FCUSI-0001 modules. Safety Manager systems running software versions prior to R140.1 do not support the FX-USI-0002 module. Upgrading to the recommended software version is strongly recommended for Safety Manager systems running earlier versions. If an upgrade is not possible in the near future, end users are advised to check for sufficient spare parts in case of failure of the FE-USI-0002, FC-USI-0002, or FC-USI-0001 modules.
Replacement Capability: This product is designed for direct online replacement of older FE-USI-0002, FC-USI-0002, and FC-USI-0001 modules.
Enhanced Functionality: While backward compatible, all advanced features are only activated when used with Safety Manager R151.1 or later.
Software Requirements: Only Safety Manager software R140.1 and later are supported.
Communication Support: Provides 16-channel signal conditioning and supports industrial protocols such as Modbus TCP and Ethernet/IP for connecting field devices to higher-level control networks.
PRODUCT & ORDER FAQS

Questions buyers ask about FX-USI-0002 V1.0

  • What are the basic uses of FX-USI-0002 V1.0 in the industrial control ecosystem?

    FX-USI-0002 V1.0 is a highly reliable universal serial interface module designed to facilitate deterministic communication between field devices and monitoring systems. As a protocol adapter and signal conditioning layer, it enables seamless interoperability of heterogeneous industrial components within a unified automation architecture.
  • Why does FX-USI-0002 V1.0 emphasize multi-protocol interoperability?

    Industrial environments often operate both legacy and modern subsystems simultaneously. FX-USI-0002 V1.0 addresses this complexity by supporting multiple communication protocols, thereby minimizing integration friction, reducing the number of gateways, and improving the lifecycle sustainability of existing infrastructure.
  • How does FX-USI-0002 V1.0 improve communication reliability in mission-critical applications?

    This module integrates robust error detection, signal isolation, and industrial-grade EMI/EMC immunity. These characteristics collectively ensure stable data transmission even in noisy environments, thus guaranteeing data integrity and maintaining deterministic system behavior.
  • What are the advantages of the FX-USI-0002 V1.0 in terms of installation and commissioning efficiency?

    The device features a plug-and-play design, simplified cabling architecture, and streamlined configuration workflow. These features reduce commissioning time, minimize human error, and accelerate system readiness.
  • Why is industrial-grade durability a key design element of the FX-USI-0002 V1.0?

    This module is designed to withstand harsh operating environments such as temperature fluctuations, vibration, and electromagnetic interference. Its industrial-grade construction ensures a long service life, short maintenance cycles, and high system availability. 7. How does FX-USI-0002 V1.0 support diagnostic transparency and troubleshooting?
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

FX-USI-0002 V1.0
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.