ICS Triplex T9300
ICS Triplex T9300
ICS Triplex T9300
ICS Triplex T9300
ICS Triplex T9300
ICS Triplex T9300
· Product image is representative; revision or series may vary. Contact us to request a specific version.

T9300

I/O Base Module
In Stock
Ships by Saturday, June 27
Fast Shipping Available

Product Information:

The ICS Triplex T9300 is an industrial I/O base unit (backplane) designed specifically for Rockwell Automation's AADvance controller systems. It operates as a passive expansion backbone, distributing system power, command buses, and response lines to plug-in I/O modules.

Electrically, this base unit integrates one command bus, 24 response buses, and a dual +24V DC redundant power distribution system for efficient transmission of multi-channel high-speed signals.

Physically, it supports direct, compact connection of multiple T9300 units via an integrated plug/socket mechanism (slot numbers 01 to 24), or extension of the bus up to 8 meters using T9310 extension cables compliant with IEC 61508 SIL 3. This safety-grade industrial process control environment provides a highly flexible and fault-tolerant modular expansion solution.

Expand All
Collapse all

Technical specifications for T9300

  • Manufacturer:
    ICS Triplex
  • Product Category:
    SIS System
  • Estimated shipping dimensions:
    23.6x13.2x3cm
  • Weight:
    0.22 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Operating Voltage:
    12-24V DC
  • Current Consumption:
    ≤150mA
  • Communication Interface:
    RS-485, Modbus RTU
  • Number of Inputs/Outputs:
    16/16 channels
  • Operating Temperature Range:
    -40°C to +85°C
  • Storage Temperature Range:
    -40°C to +125°C
  • Relative Humidity:
    5% to 95% non-condensing
  • Product Type:
    I/O Base Module
  • Category Series:
    AADvance controller systems
  • Maximum Pass-Through Current:
    9.6 A total
  • Mounting Hardware:
    Standard DIN rail mounting
  • Stock:
    100

Alternative Names

T93OO T9401 T9402 T9451 T9431 T9432 T9481 T9482 T9801 T9100 T9110 T9802 T9803 T9831 T9832

Information

Overview Manuals Important Installation & Power Interlock Warning

Features:

  • Features a top and bottom retention clip mechanism to interlock adjacent bases
  • Passive PCB housed in heavy-duty, industrial-grade plastic molding
  • Position the I/O module onto the alignment dowel pins of the T9300
AADvance T9300 I/O base units connect to the right hand side of the T9100 processor base unit (I/O Bus 1) and to the right hand side of other T9300 I/O base units by a direct plug and socket connection. The I/O base units connect to the left hand side of the processor base unit by using the T9310 expansion cable (I/O Bus 2). The expansion cable also connects the right hand side of I/O base units to the left hand side of other I/O base units to install extra rows of I/O base units. Base units are secured in place by top and bottom clips that are inserted into the slots on each base unit.

Each physical T9300 base unit supports up to three (3) I/O modules (such as digital input/output or analog input/output cards) and their corresponding termination assemblies.

The T9300 ICS triplex I/O Base Module may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
ICS Triplex T9300 I/O Base Module maunal(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
When installing the I/O module onto the T9300 backplane:
 
1. Align the I/O module with the T9300's locating pin.
2. Press the module firmly until the backplane locating pin is fully inserted into the base.
3. Using a 9mm wide-tip flathead screwdriver, turn the module's retaining screw clockwise by one-quarter turn.
4. Important: This locking screw acts as a physical power interlock. If not locked, the T9300 base will refuse to power or configure the module, triggering a hardware failure loop.

Technical notes

The ICS Triplex T9300, manufactured by ICS Triplex, a subsidiary of Rockwell Automation, is an I/O base unit designed specifically for AADvance control systems. As the physical expansion core for the system's distributed I/O, it employs a passive backplane design. Each base provides three I/O module slots (supporting any type of input/output module and corresponding field terminals).

Ask our team:

  • How does the T9300 leverage its high integrity fault-tolerant architecture and redundant communication framework to ensure deterministic control execution in safety-critical automation systems?
    The T9300 is designed to provide reliable processing, fault isolation, and continuous operational availability for mission-critical industrial applications.
  • Why is the T9300 considered a strategic component of high-availability safety systems requiring operational integrity and resilient processing performance oriented towards Safety Integrity Level (SIL)?
    The T9300 supports advanced safety and availability goals by providing reliable system monitoring and robust operational continuity.
  • How does the T9300 maintain deterministic response time, communication consistency, and fault-tolerant operation under abnormal process conditions?
    The T9300 integrates advanced fault detection and system monitoring mechanisms to maintain operational stability under harsh conditions.
  • Which key technical specifications of the T9300 should engineers evaluate, including communication interfaces, redundancy mechanisms, environmental ratings, and processing capabilities?
    A comprehensive evaluation of the T9300 specifications helps ensure its proper integration into high-integrity industrial control systems.
  • Why should engineers carefully evaluate the T9300's redundancy architecture, communication bandwidth, and diagnostic coverage before system deployment?
    Proper evaluation of the T9300 ensures it meets the reliability, security, and availability requirements of specific applications.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.