TC-001-02-6M0

Chassis Power Cable
In Stock

Product Information:

Chassis Power Cable

(MCB Distribution Unit to Expander

Chassis in an adjacent bay)

Used to connect 24 Vdc from a Power

Distribution Unit MCB

(T8292) to a Trusted Controller or

Expander Chassis

Expand All
Collapse all

Technical specifications for TC-001-02-6M0

  • Manufacturer:
    ICS Triplex
  • Product Category:
    PLC System
  • Estimated shipping dimensions:
    12 x 11.3 x 10.6 cm
  • Weight:
    0.2 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Product Type:
    Chassis Power Cable
  • Category Series:
    Trusted TC000 Series
  • Cable Length:
    6.0 m
  • Power Consumption:
    24 Vdc to 125 Vac
  • Main Type:
    Low Smoke Zero Halogen (LSZH), halogen-free, and flame-retardant cable.
  • IP degree of protection:
    IP 20
  • Stock:
    20

Information

Overview Manuals Main Features Related Cables in the Series

Features:

  • ICS Triplex Chassis Power Cable unit
  • Trusted TC000 Power Cables module
  • MCB Distribution Unit to Expander Chassis in an adjacent bay
The Trusted TC000 Power Cable is specifically engineered to provide a reliable electrical interface between the Power Distribution Unit Miniature Circuit Breaker (MCB) T8292 and the Fan Assembly T8270 within a Trusted system architecture. This cable functions as a dedicated power transmission link, ensuring stable and uninterrupted delivery of supply voltage from the protection device (MCB) to the cooling subsystem. Its configuration supports controlled current flow while maintaining electrical isolation and operational safety within the cabinet infrastructure.

Designed for integration in high-availability and safety-critical control environments, the Trusted TC000 Power Cable incorporates robust insulation, secure termination interfaces, and precise connector compatibility with both T8292 and T8270 components. The cable assembly ensures minimal voltage drop, controlled thermal performance, and resistance to mechanical stress commonly encountered in control panels and industrial enclosures. Its construction supports consistent performance under continuous duty cycles, contributing to overall system reliability and thermal management efficiency.

The TC-001-02-6M0 ICS Triplex Chassis Power Cable may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
ICS Triplex TC-001-02-6M0 Chassis Power Cable Manuals(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
From a system engineering perspective, the Trusted TC000 Power Cable plays a vital role in sustaining the operational integrity of the cooling mechanism associated with the Trusted platform. By ensuring dependable power continuity from the T8292 MCB to the T8270 Fan Assembly, the cable supports effective heat dissipation, thereby safeguarding electronic modules from thermal overload conditions. Proper installation, routing discipline, and adherence to electrical load specifications are essential to maintaining optimal performance and long-term durability of the power distribution pathway.
  • Part Number Length Typical Application
  • TC-001-02-1M5 1.5 m Distribution Unit to first Controller/Expander chassis
  • TC-001-02-2M5 2.5 m Distribution Unit to 2nd or 3rd Expander chassis
  • TC-001-02-6M0 6.0 m Connection to chassis in an adjacent bay
  • TC-001-03-XXX Various UL Certified versions of the same power cables

Ask our team:

  • What are the main functions of the TC-001-02-6M0 in industrial sensing and signal transmission infrastructure?
    The TC-001-02-6M0 is a precision interconnect and signal transmission component designed to ensure reliable data transmission between field sensors and monitoring systems.
  • How does the TC-001-02-6M0 maintain signal fidelity in highly interference-prone industrial environments?
    The TC-001-02-6M0 employs optimized conductor design and shielding technology to minimize electromagnetic interference and maintain signal accuracy.
  • Why is the TC-001-02-6M0 crucial for precise temperature and process measurement applications?
    The TC-001-02-6M0 supports stable transmission of low-level sensor signals, enabling precise monitoring of industrial processes.
  • In what ways does the TC-001-02-6M0 enhance electromagnetic compatibility (EMC) performance?
    The TC-001-02-6M0 integrates shielding and grounding strategies to reduce noise coupling and maintain measurement reliability.
  • What are the installation advantages of the TC-001-02-6M0 in industrial automation systems?
    The TC-001-02-6M0's durable construction and standardized connections simplify installation and long-term operation.
  • How does the TC-001-02-6M0 perform under harsh environmental and mechanical conditions?
    The TC-001-02-6M0 is designed to withstand the vibrations, temperature fluctuations, and electrical noise common in industrial facilities.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.