NI NATIONAL INSTRUMENTS PCI-5122
NI NATIONAL INSTRUMENTS PCI-5122
· Product image is representative; revision or series may vary. Contact us to request a specific version.

PCI-5122

Digital Calibration Procedure
In Stock
Ships by Saturday, June 27
Fast Shipping Available

Product Information:

The PCI-5122 is a high-resolution 14-bit dual-channel digital oscilloscope card designed for the standard PCI bus and manufactured by National Instruments (NI). With its low-distortion analog front-end and deep data stream storage architecture, it is widely used in automated test systems, scientific research, and high-speed data acquisition.

This oscilloscope card features highly flexible edge, window, video, and digital trigger engines (supporting 100 ps-level high-precision timestamp counting). In multi-record acquisition mode, it can continuously acquire up to 100,000 trigger waveforms without software intervention.

It supports seamless integration into LabVIEW or C/C++ development environments via standard NI-SCOPE drivers, making it ideal for high-precision acquisition of weak time and frequency domain signals in fields such as automotive electronics, ultrasound medicine, radar communications, and scientific research.

Expand All
Collapse all

Technical specifications for PCI-5122

  • Manufacturer:
    NI NATIONAL INSTRUMENTS
  • Product Category:
    General Automation
  • Estimated shipping dimensions:
    15.2 x 14.6 x 19 cm
  • Weight:
    0.55 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Ambient temperature range:
    0 °C to 55 °C
  • Relative humidity range:
    10% to 90%
  • Maximum altitude:
    2,000 m (at 25 °C ambient temperature)
  • Input impedance (softwareselectable):
    50 Ω ± 2.0%
  • Maximum input overload:
    7 Vrms with |Peaks| ≤10 V
  • Impedance:
    50 Ω
  • Maximum drive current:
    ±48 mA
  • Logic type:
    3.3 V CMOS
  • Maximum drive current:
    ±12 mA
  • Maximum frequency:
    25 MHz
  • Number of channels:
    2 simultaneously sampled
  • Vertical resolution:
    14 bits
  • Bandwidth1 (-3 dB):
    100 MHz
  • Stock:
    10

Alternative Names

PCI5122 PCI 5122 PC1-5122 PCI-5I22 PC1-5I22 PXI-5122 PXI 5122 PXI5122 PX1-5122 PXI-5I22 PX1-5I22

Information

Overview Manuals Working principle Application & Integration

Features:

  • High-resolution, 14-bit digital oscilloscope (digitizer)
  • Designed for PCI-based automated test and measurement systems
  • Used for tasks requiring precise time-domain and frequency-domain analysis
This module features two synchronous sampling channels with 14-bit resolution and a maximum real-time sampling rate of 100 MS/s, making it ideal for high-precision, wide dynamic range, and high-frequency signal acquisition. This powerful module offers a wide input range of 200 mV to 20 V and abundant onboard memory options, enabling lossless acquisition of signals with long durations and complex waveforms.

It is fully integrated with NI-SCOPE driver software, allowing seamless synchronization with other instruments via the PXI/PCI bus, and supports advanced trigger modes for precise signal isolation and analysis.

The PCI-5122 NI NATIONAL INSTRUMENTS Digital Calibration Procedure may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
NI NATIONAL INSTRUMENTS PCI-5122 Digital Calibration Procedure manual(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
In terms of operation, the PCI-5122 first scales and filters the input analog signal through a high-fidelity front-end circuit before sending it to a high-speed analog-to-digital converter (ADC). These ADCs sample the signal at fixed time intervals, converting instantaneous voltages into 14-bit digital data. The data is then transferred to the onboard memory via a high-speed controller that uses a reference clock to manage timing and synchronization, ensuring jitter-free data acquisition on both channels.
  1. Software Compatibility: Fully integrated with NI LabVIEW, LabWindows/CVI, and Measurement Studio. It uses the NI-SCOPE driver, which includes over 50 built-in measurement and analysis functions.
  2. Common Applications: Used for ultrasonic and radar signal processing, event detection, and high-channel-count simultaneous measurements when multiple modules are connected.
  3. Physical Configuration: Requires a standard PCI expansion slot. It features a BNC female connector for analog inputs and external triggering.

Technical notes

The PCI-5122 is a high-resolution, low-noise, high-speed oscilloscope/digitizer card from National Instruments (NI) based on the PCI bus architecture. This card features two synchronously sampled analog input channels, a high 14-bit vertical resolution, 100 MHz analog bandwidth, and a real-time sampling rate of 100 MS/s (up to 2.0 GS/s in Random Interleaved Sampling (RIS) mode).

Ask our team:

  • What is the architectural purpose of the PCI-5122 in high-precision data acquisition and measurement infrastructure?
    The PCI-5122 is a widely recognized high-resolution digitizer designed for advanced signal acquisition tasks, enabling accurate waveform capture, high-speed sampling, and fine signal analysis in laboratory and industrial test environments.
  • How does the PCI-5122 support high-speed sampling and deep memory acquisition for transient and dynamic signal analysis?
    The PCI-5122 is carefully designed to provide high sampling rates and large-capacity onboard memory, enabling long-term acquisition and fine transient analysis without compromising temporal resolution.
  • What software ecosystem and driver support does the PCI-5122 provide for integration with advanced measurement applications?
    The PCI-5122 typically supports driver frameworks and application programming interfaces (APIs) for easy integration with engineering software environments used for signal processing, visualization, and automation.
  • How does the PCI-5122 support advanced signal analysis applications such as RF testing, power electronics characterization, and scientific research?
    The PCI-5122 enables high-resolution signal acquisition and accurate waveform reconstruction, making it suitable for demanding applications requiring precise measurements, spectrum analysis, and detailed signal diagnostics.
  • What role does the PCI-5122 play in automated test and measurement (ATE) systems requiring repeatable and deterministic acquisition cycles?
    The PCI-5122 is designed for seamless integration into automated test platforms, enabling deterministic acquisition workflows and repeatable measurement sequences, crucial for validation and production testing.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.