Vibro-Meter CP235 143-235-000-012
Vibro-Meter CP235 143-235-000-012
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Saturday, September 12
Fast Shipping Available
Dynamic Pressure Sensor

CP235 143-235-000-012

Spare Part Number

PNCP235 143-235-000-012

Product Information:

Part number CP235 (configuration code: 143-235-000-012) represents the Meggitt vibro-meter® high-sensitivity piezoelectric dynamic pressure sensor. Similar to the CP515, this sensor is a dedicated, rugged industrial sensor for continuously monitoring pulsating and dynamic pressure changes within the combustion chamber of land-based gas turbines. It utilizes a synthetic piezoelectric crystal material and is specially designed to provide a highly stable charge output while maintaining low sensitivity to mechanical housing acceleration.
Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
Technical specifications for

CP235 143-235-000-012

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Vibro-Meter
  • Product Category:
    Sensor
  • Spare Part Number:
    CP235 143-235-000-012
  • Estimated shipping dimensions:
    12.5 x 10 x 14 cm
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Input power requirements:
    None
  • Signal transmission:
    2-pole system insulated from casing, charge output
  • Operating (at +23°C ±5°C) Sensitivity (at 2 Hz):
    750 pC/bar (52 pC/psi) min
  • Static pressure (on sensing head):
    0.1 to 20 bar
  • Dynamic measuring range (random):
    0.00005 to 5 bar nom
  • Overload capacity (spikes):
    Up to 100 bar (1450 psi) (static + dynamic components)
  • Linearity:
    ≤±1% over dynamic measuring range
  • Resonant frequency:
    >55 kHz (along sensitive axis)
  • Capacitance (nominal) Pole to pole:
    700 pF for transducer + 200pF/m for cable
  • Internal insulation resistance:
    Min. 109 Ω (5x104 Ω at 520°C)
  • Temperature range:
    −55 to +520°C (−67 to 968°F) continuous operation
  • Shock acceleration:
    ≤1000 g peak (half sine-wave, 1 ms duration) along sensitive axis
  • Corrosion, humidity:
    INCONEL® 600, hermetically welded
  • Cable Length:
    2 m cable length
  • Series:
    Vibro-Meter Sensors and Measurement Chains
  • Stock:
    100
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The part is inspected, tested and securely packed before dispatch, with tracking provided after release.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

CP235 143-235-000-012 CP235 143 235 000 012 CP235 I43-235-000-0I2 CP235 143-235-OOO-O12 CP 235 143-235-000-012 CP 235 143-235-000-022 CP 235 143-235-000-022 CP235 143-235-000-022

Information

Overview Manuals Measuring Chain & Signal Processing

Features:

  • Base model designation for the high-sensitivity dynamic pressure sensor series
  • Indicates a factory-integrated, 2-meter (6.6 ft.) mineral-insulated (MI)
  • Terminated with a specialized Vibro-Meter high-temperature connector
The core function of this sensor is to perform long-term, continuous online monitoring of pressure pulsations in harsh environments such as gas turbine combustion chambers. It boasts an extremely high charge sensitivity of up to 750 pC/bar and excellent high-temperature resistance, operating stably at temperatures up to 520 °C. This enables it to capture sensitive combustion instabilities and acoustic oscillations in industrial environments in real time.

In order to provide accurate data in the operation of complex large machinery, its internal structure has been specially optimized to minimize its sensitivity to mechanical acceleration (lateral and axial vibration), thereby effectively filtering out false interference signals caused by background vibration.

The CP235 143-235-000-012 Vibro-Meter Dynamic Pressure Sensor may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Vibro-Meter CP235 143-235-000-012 Dynamic Pressure Sensor manual(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The raw output signal of the CP235 is a high-impedance static charge. To process it and integrate it into a factory monitoring system, a standard Vibro-meter® loop architecture must be used:
Charge Amplifier/Signal Conditioner: Located downstream of the IPC704 signal conditioner. The IPC704 converts the pC charge output into a linear, low-impedance current signal (typically transmitted over two wires).
System Interface: Signals from the IPC module are routed directly to a mechanical protection system card, such as a VM600 MPC4 card or a distributed VibroSmart® module.

Technical notes

The Meggitt Vibro-Meter CP235 (143-235-000-012) is a piezoelectric dynamic pressure sensor designed for the high-pressure, high-temperature extreme environments of gas turbine combustion chambers. It features an operating temperature range of -55°C to 520°C and high sensitivity. The sensor utilizes a built-in 2-meter mineral-insulated cable, incorporates acceleration compensation to reduce interference, and is typically used with an IPC704 signal modulator to meet ATEX/IECEx explosion-proof requirements.
PRODUCT & ORDER FAQS

Questions buyers ask about CP235 143-235-000-012

  • How does the CP235 143-235-000-012 leverage its precision signal transmission architecture and industrial-grade connectivity design to ensure high-reliability vibration monitoring performance?

    The CP235 143-235-000-012 is designed for critical machinery monitoring applications, providing reliable signal transmission and stable operating characteristics.
  • Why is the CP235 143-235-000-012 considered a high-reliability interconnect solution for advanced machinery protection systems requiring superior signal fidelity?

    The CP235 143-235-000-012 supports precise signal transmission between monitored components while maintaining reliable performance in industrial environments.
  • What operational advantages does the CP235 143-235-000-012 offer with its robust construction, optimized electrical characteristics, and industrial-grade reliability specifications?

    The CP235 143-235-000-012 enhances monitoring system performance by supporting stable and consistent signal communication.
  • Why should engineers evaluate the electrical compatibility, connectivity characteristics, environmental rating, and system integration requirements of the CP235 143-235-000-012 before implementation?

    A detailed analysis of the CP235 143-235-000-012 specifications helps ensure optimal system performance and long-term reliability.
  • Which key technical parameters of the CP235 143-235-000-012, including electrical performance characteristics, mechanical compatibility, installation requirements, and environmental tolerance, should be evaluated?

    Engineers should validate all operating specifications of the CP235 143-235-000-012 to maximize the effectiveness of the monitoring system.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

CP235 143-235-000-012
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.