Get Repair Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
Vibro-Meter CP232 143-232-000-222
Vibro-Meter CP232 143-232-000-222
· Product image is representative; revision or series may vary. Contact us to request a specific version.

CP232 143-232-000-222

High-sensitivity piezoelectric dynamic pressure sensor
In Stock
Ships by Tuesday, June 23
Fast Shipping Available

Product Information:

Part number CP232 (configuration code: 143-232-000-222) represents the Meggitt vibro-meter® high-sensitivity piezoelectric dynamic pressure sensor. This extreme environment sensor is designed for condition monitoring and predictive maintenance of industrial rotating machinery. It is most commonly used to measure high-frequency combustion chamber pulsations and thermoacoustic instabilities in land-based gas turbines, steam turbines, and aircraft engine test benches.
Expand All
Collapse all

Technical specifications for CP232 143-232-000-222

  • Manufacturer:
    Vibro-Meter
  • Product Category:
    General Automation
  • Estimated shipping dimensions:
    12.5 x 10 x 14 cm
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Product Type:
    Dynamic Pressure Sensor
  • Measurement Range:
    Capable of handling rated pressures up to 100 bar (10 MPa)
  • Charge Sensitivity:
    >750 pC/bar
  • Operating Temperature:
    -50°C to +777°C
  • Frequency Range (-3 dB):
    Up to 15,000 Hz (15 kHz)
  • Current consumption:
    4-20 mA
  • Humidity:
    95% RH (no condensation)
  • Storage Temperature:
    0°C to +777°C
  • Stock:
    100

Alternative Names

CP232 143-232-000-222 CP232 I43-232-000-222 CP232 143-232-OOO-222 I43-232-000-222 143-232-OOO-222 143-232-000-111 143-232-000-112 CP 232 CP 232 143-232-000-222 CP232 143-232-000-111 CP232 143-232-000-112 CP232 I43-232-OOO-222

Information

Overview Manuals Hazardous Area Safety Ratings System Loop Integration

Features:

  • Delivers a minimum output of 750 pC/bar (approx. 52 pC/psi)
  • It features patented internal acceleration compensation technology to prevent structural engine vibrations from contaminating the true acoustic pressure data
  • Built using specialized VC2 single-crystal piezoelectric material operating in a compression mode
Vibro-Meter's core function is to provide high-end condition monitoring and machinery protection systems for critical industries worldwide, including aerospace, power generation, heavy industry, and oil and gas. Its product line encompasses high-performance dynamic pressure sensors, vibration sensors, bearing vibration monitoring probes, and fully automated data acquisition and diagnostic systems.

Its systems can reliably acquire extremely subtle physical change data in harsh field environments (such as ultra-high temperatures above 500°C, extremely high mechanical shocks, and potentially explosive environments), and can transform these complex physical signals into intuitive machine condition analyses through central monitoring software (such as the VM600 series system).

The CP232 143-232-000-222 Vibro-Meter High-sensitivity piezoelectric dynamic pressure sensor may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Vibro-Meter CP232 143-232-000-222 High-sensitivity piezoelectric dynamic pressure sensor manual(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
According to official records from the Parker Meggit Hazardous Products Registry, this specific suffix configuration has been certified for the following European explosion-proof categories: Intrinsically safe: Classified as II 2 G Ex ib IIC T6...560°C Gb according to LCIE 02 ATEX 6105 X certificate. Non-sparking (Zone 2): Individually rated as II 3 G Ex nA IIC T6...560°C Gc according to LCIE 09 ATEX 1039 X certificate.
Because the CP232 outputs a raw, high-impedance static charge analog signal, it cannot be directly connected to standard control systems. It relies on a multi-component measurement chain:

Signal Conditioning: The charge signal is transmitted via an insulated cable to a local charge amplifier, typically a Meggitt IPC707 signal conditioner. (Note: Due to high impedance limitations, the CP232 sensor is incompatible with standard IPC707 diagnostic cards when using integrated mineral-insulated cables longer than 0.3 meters.)
Rack Protection System: The converted low-impedance linear current loop connects directly to the factory machinery protection box, such as a VM600 rack-mounted MPC4 card, for automatically recording machinery emergency trips and shutdown data.

Technical notes

The Meggitt Vibro-Meter CP232 (143-232-000-222) is a high-sensitivity piezoelectric dynamic pressure sensor designed specifically for gas turbines. It can operate in environments up to 777°C and employs acceleration compensation technology to eliminate vibration interference. With a charge sensitivity of >750 pC/bar and a high-frequency response, this sensor meets the pressure monitoring requirements under extreme conditions.

Ask our team:

  • How does the CP232 143-232-000-222 leverage its sophisticated signal transmission architecture and industrial-grade electrical characteristics to ensure high-fidelity mechanical monitoring performance?
    The CP232 143-232-000-222 is designed to provide reliable signal transmission and stable operational performance for advanced condition monitoring systems.
  • Why is the CP232 143-232-000-222 considered a critical connectivity component for vibration monitoring infrastructure, meeting the demands for superior signal integrity and long-term reliability?
    The CP232 143-232-000-222 supports reliable communication between monitoring devices while maintaining measurement accuracy throughout the system.
  • What operational advantages does the CP232 143-232-000-222 offer due to its robust industrial construction, optimized electrical performance, and mechanical protection compatibility?
    The CP232 143-232-000-222 enhances the effectiveness of monitoring systems by ensuring stable and reliable signal transmission.
  • When deploying the CP232 143-232-000-222 in a high-performance rotating equipment monitoring environment, how can signal linearity be maintained and transmission attenuation minimized?
    The CP232 143-232-000-222 is designed to maintain signal quality and measurement consistency under harsh operating conditions.
  • Which key technical parameters of the CP232 143-232-000-222, including electrical performance characteristics, mechanical structure, environmental tolerance, and connection specifications, should be analyzed?
    Engineers should verify all operating specifications of the CP232 143-232-000-222 to maximize the effectiveness of the monitoring system.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.