Vibro-Meter TQ402 111-402-000-012
Vibro-Meter TQ402 111-402-000-012
· Product image is representative; revision or series may vary. Contact us to request a specific version.

TQ402 111-402-000-012

Non-contact eddy current proximity sensor
In Stock
Ships by Tuesday, June 23
Fast Shipping Available

Product Information:

The TQ402 (part number 111-402-000-012) is a high-precision non-contact eddy current proximity sensor manufactured by Meggitt (vibro-meter®). The suffix string is omitted; this basic part number represents a threaded body sensor hardware platform used to monitor relative shaft vibration, axial position, and thermal expansion of critical rotating machinery.

Expand All
Collapse all

Technical specifications for TQ402 111-402-000-012

  • Manufacturer:
    Vibro-Meter
  • Product Category:
    General Automation
  • Estimated shipping dimensions:
    10 x 11 x 14.6 cm
  • Weight:
    0.44 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Frequency response:
    DC to 20 kHz (−3 dB)
  • Measurement range:
    2 or 4 mm
  • Temperature range:
    −40 to +180 °C
  • Temperature ranges Transducer:
    −40 to +180°C with drift <5% (operating)
  • Transducer and cable:
    −40 to +195°C if used in an Ex Zone
  • Protection rating (according to IEC 60529):
    The head of the proximity transducer (transducer tip and integral cable) is rated IP68
  • Vibration:
    5 g peak between 10 and 500 Hz
  • Shock acceleration:
    15 g peak (half sine-wave, 11 ms duration)
  • Product Type:
    Non-contact eddy current proximity sensor
  • Category Series:
    TQ402 Series
  • Stock:
    100

Alternative Names

TQ402 111-402-000-012 TQ402 111 402 000 012 TQ 402 111-402-000-012 TQ 402 TQ402 111-402-000-012 A1-B1-D000-E010-F0-G000-H05 TQ402 111-402-000-013 S3960 A1-B1-C042-D000-E010-F0-G000-H10 TQ402 111-402-000-013 111-402-000-013 TQ402 111-402-000-013 S3960 TQ 402 111-402-000-013 S3960

Information

Overview Manuals Functional Breakdown Paired Ancillary Equipment

Features:

  • Non-contact measurement system based on eddy current principle
  • Voltage or current output with protection against short circuits
  • Temperature compensated system, 1 m, 5 m and 10 m systems
The active part of the transducer is a coil of wire that is moulded inside the tip of the device, made of Torlon ® (polyamide-imide). The transducer body is made of stainless steel. The target material must, in all cases, be metallic. The transducer body is available with metric or imperial thread. The TQ 412 version is intended for reverse-mount applications. The TQ 402 / 412 has an integral coaxial cable, terminated with a self-locking miniature coaxial connector. Various cable lengths (integral and extension) can be ordered.

The TQ 402 and TQ 412 transducers can be matched with a single EA 402 extension cable to effectively lengthen the front-end. Optional housings, junction boxes and interconnection protectors are available for the mechanical and environmental protection of the connection between the integral and extension cables. The proximity system can be powered by associated signal processing modules (for example, VM600 cards) or a rack power supply.

The TQ402 111-402-000-012 Vibro-Meter Non-contact eddy current proximity sensor proximity sensor may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Vibro-Meter TQ402 111-402-000-012 Non-contact eddy current proximity sensor manual(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Sensor Type: Standard mounting proximity probe with an 8 mm tip diameter.
Measurement Output: Transmits high-frequency eddy current signal variations caused by changes in the gap between the sensor tip and the target axis.
Compliance: Designed to meet API 670 mechanical protection system requirements.
When used with downstream hardware, this probe forms a complete measurement loop:
Extension cable: Meggitt EA402 series (use this extension cable if the probe cannot be directly connected to the transmitter).
Signal conditioning: The Meggitt IQS900 or earlier IQS450 module converts the sensor output into a standard analog voltage or current loop signal.

Technical notes

The Meggitt Vibro-Meter TQ402 (part number: 111-402-000-012) is an API 670 compliant industrial-grade 8mm non-contact eddy current displacement sensor probe designed for monitoring axial displacement and relative shaft vibration in rotating machinery such as steam turbines, gas turbines, and water pumps. Featuring a stainless steel housing and a high-temperature Torlon® probe, this sensor operates stably for extended periods in extreme environments ranging from -40°C to +180°C.

Ask our team:

  • How does the TQ402 111-402-000-012 utilize eddy current sensing technology to achieve micron-level non-contact displacement measurement in high-speed rotating machinery applications?
    The TQ402 111-402-000-012 employs advanced eddy current proximity sensing principles, designed to provide high-precision shaft displacement and vibration measurements.
  • Why is the TQ402 111-402-000-012 considered a high-linearity proximity sensor suitable for turbomachinery monitoring systems requiring superior measurement stability and repeatability?
    The TQ402 111-402-000-012 offers accurate and repeatable measurement performance, making it suitable for critical machinery protection applications.
  • How does the TQ402 111-402-000-012 differ from traditional displacement probes in terms of sensitivity optimization, electromagnetic field stability, and dynamic response characteristics?
    The TQ402 111-402-000-012 is designed for superior measurement accuracy, fast response time, and long-term operational reliability.
  • Why should engineers carefully evaluate the probe diameter, measurement range, target material compatibility, and calibration parameters of the TQ402 111-402-000-012 before system integration?
    Properly evaluating the specifications of the TQ402 111-402-000-012 ensures optimal performance and accurate measurement results.
  • Which key technical parameters of the TQ402 111-402-000-012 should be analyzed, including sensitivity coefficient, linear measurement range, frequency response, and environmental operating limitations?
    It is recommended to review the technical specifications of the TQ402 111-402-000-012 in detail to maximize the efficiency and reliability of the monitoring system.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.