Omron NE2A-DNS21
Omron NE2A-DNS21
Omron NE2A-DNS21
Omron NE2A-DNS21
Omron NE2A-DNS21
Omron NE2A-DNS21
· Product image is representative; revision or series may vary. Contact us to request a specific version.

NE2A-DNS21

DeviceNet Safety Unit
In Stock

Product Information:

DeviceNet Safety Unit

Safety Network Controller

used within the NE2A series

for industrial automation

designed to integrate safety control

and standard information control

within a single network

supporting both DeviceNet Safety

and DeviceNet Standard communications

Expand All
Collapse all

Technical specifications for NE2A-DNS21

  • Manufacturer:
    Omron
  • Product Category:
    General Automation
  • Estimated shipping dimensions:
    15.2 x 20 x 12.3 cm
  • Weight:
    0.6 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Product Type:
    DeviceNet Safety Unit
  • Power Supply:
    24 V DC
  • Input Type:
    16 digital input channels
  • Communication ports:
    RS-485 or RS-232C
  • Ambient temperature range:
    -10°C to +70°C
  • Operating Voltage:
    120 Vac (+10, -15%)
  • Stock:
    10

Information

Overview Manuals In terms of operation Applications and System Configuration

Features:

  • DeviceNet Safety Unit Safety Network Controller
  • Used within the NE2A series for industrial automation
  • Designed to integrate safety control and standard information control within a single network
Its primary function is to act as a bridge between safety-grade field devices and the standard DeviceNet network, seamlessly integrating safety I/O (such as emergency stop buttons and light curtains) into distributed control architectures.

By providing highly reliable communication, it ensures that safety-critical data is transmitted with the necessary integrity to meet international safety standards such as SIL3 or PLe. In addition to basic communication functions, the module offers robust diagnostic capabilities and flexible I/O management.

The NE2A-DNS21 Omron DeviceNet Safety Unit may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Omron NE2A-DNS21 DeviceNet Safety Unit INFO(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The NE2A-DNS21 utilizes the CIP Safety (Common Industrial Protocol Safety) protocol based on the DeviceNet physical layer. It continuously performs a dual-channel cross-check mechanism on all incoming safety signals to detect internal hardware faults or external line faults, such as short circuits. When a safety event occurs or a communication error is detected, the module immediately switches to a predefined "safe state" (typically shutting down all outputs) and broadcasts a high-priority safety message to the main controller to initiate an emergency stop or safe shutdown of the entire network.
  • The NE2A-DNS21, installed on NE2A series controllers, is a key component in building safety networks for monitoring safety-critical devices such as emergency stop buttons and light curtains.
  • Integration: Easily integrates with Omron controllers and can be configured using Sysmac Studio or network configuration tools.
  • Versatility: Suitable for applications such as robotics, CNC machining, material handling, and packaging machinery.

Ask our team:

  • How does the NE2A-DNS21 achieve secure authentication communication over Industrial Ethernet or DeviceNet secure networks?
    The NE2A-DNS21 typically employs secure protocol encapsulation, cyclic redundancy verification, and deterministic message processing to ensure compliance with functional safety communication standards.
  • How does the NE2A-DNS21 support integration between safety controllers and distributed secure I/O architectures?
    The NE2A-DNS21 is typically used as a communication gateway, connecting safety controllers to remote safety devices to ensure reliable transmission of safety signals and coordinated system responses.
  • How does the NE2A-DNS21 ensure data integrity and fault tolerance during safety-critical communication cycles?
    The NE2A-DNS21 integrates robust error detection mechanisms, including redundancy checks, timestamped message passing, and watchdog monitoring, to maintain the reliability of secure communication.
  • What configuration flexibility does the NE2A-DNS21 offer in terms of debugging and secure network topology design?
    The NE2A-DNS21 typically supports configurable network parameters, node addressing, and secure connection mapping to adapt to various machine security architectures.
  • How does the NE2A-DNS21 facilitate scalable, modular secure network expansion?
    The NE2A-DNS21 supports additional secure nodes and flexible network topologies, enabling modular system expansion without requiring a fundamental redesign of the security architecture.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.