9200-Axx-Bxx-Cxx-Dxx
A: Transducer Mounting Angle/Minimum
Operating Frequency
01: 0 ±2.5, 4.5 Hz (270 cpm)
02: 45 ±2.5, 4.5 Hz (270 cpm)
03: 90 ±2.5, 4.5 Hz (270 cpm)
06: 0 ±100, 10 Hz (600 cpm)
09: 0 ±180, 15 Hz (900 cpm)
B: Connector/Cable
01: Top Mount (no cable)
02: Side Mount (no cable)
05: Terminal block top mount (no cable)
10: 10 feet (3.0 meter)
15: 15 feet (4.6 meter)
22: 22 feet (6.7 meter)
32: 32 feet (9.8 meter)
50: 50 feet (15.2 meter)
C: Mounting Base
01: Circular; 1/4-20 UNC stud
02: Circular; 1/4-28 UNF stud
03: Rectangular flange
04: Circular; with three 8-32 threaded studs on a 44 mm (1.75 in) diameter bolt circle
05: No base; 1/2-20 UNF-3A stud
06: Isolated circular 1/4-20 UNC stud
07: Isolated circular 1/4-28 UNF stud
08: Isolated rectangular flange
09: Isolated circular 5/8-18 UNF stud
10: Circular; M10X1 stud
11: Isolated circular M10X1
12: Isolated circular 1/2-20 UNF-2A
D: Agency Approval
00: No Approvals
01: CSA
04: ATEX/IECEx